Multiquip DCA85usJ2 manual General Information

Page 16

GENERAL INFORMATION

GENERATOR

This generator (Figure 3) is a high quality portable (requires a trailer for transport) power source for telecom sites, lighting facilities, power tools, submersible pumps and other industrial and construction machinery.

ENGINE OPERATING PANEL

The “Engine Operating Panel” is provided with the following:

Tachometer

Water Temperature Gauge

Oil Pressure Gauge

Charging Ammeter Gauge

Fuel Level Gauge

Panel Light/Panel Light Switch

ECU Controller

Engine Speed Switch

Emergency Stop Lamp

Warning Lamp

Pre-Heat Lamp

Fuel Leak Detected Alarm Lamp

Diagnostic Gauge

GENERATOR CONTROL PANEL

The “Generator Control Panel” is provided with the following:

Frequency Meter (Hz)

AC Ammeter (Amps)

AC Voltmeter (Volts)

Ammeter Change-Over Switch

Voltmeter Change-Over Switch

Voltage Regulator

3-Pole, 250 amp Main Circuit Breaker

“Control Box” (located behind the Gen. Control Panel)

Automatic Voltage Regulator

Current Transformer

Over-Current Relay

Starter Relay

Voltage Selector Switch

OUTPUT TERMINAL PANEL

The “Output Terminal Panel” is provided with the following:

Three 120/240V output receptacles (CS-6369), 50A

Three auxiliary circuit breakers, 50A

Two 120V output receptacles (GFCI), 20A

Two GFCI circuit breakers, 20A

Five output terminal lugs (3Ø power)

OPEN DELTA EXCITATION SYSTEM

This generator is equipped with the state of the art “Open- Delta” excitation system. The open delta system consist of an electrically independent winding wound among stationary windings of the AC output section.

There are four connections of the open delta A, B, C and D. During steady state loads, the power from the voltage regulator is supplied from the parallel connections of A to B, A to D, and C to D. These three phases of the voltage input to the voltage regulator are then rectifi ed and are the excitation current for the exciter section.

When a heavy load, such as a motor starting or a short circuit occurs, the automatic voltage regulator (AVR) switches the confi guration of the open delta to the series connection of B to C. This has the effect of adding the voltages of each phase to provide higher excitation to the exciter section and thus better voltage response during the application of heavy loads.

The connections of the AVR to the AC output windings are for sensing only. No power is required from these windings. The open-delta design provides virtually unlimited excitation current, offering maximum motor starting capabilities. The excitation does not have a “fixed ceiling” and responds according the demands of the required load.

ENGINE

This generator unit incorporates an John Deere 6068HF285 diesel engine. This engine is designed to meet every performance requirement for the generator. Reference Table 2 for engine specifi cations.

In keeping with MQ Power’s policy of constantly improving its products, the specifi cations quoted herein are subject to change without prior notice.

ELECTRIC GOVERNOR SYSTEM

The electric governor system controls the RPMs of the engine. When the engine demand increases or decreases, the governor system regulates the frequency variation to ±.25%.

EXTENSION CABLES

When electric power is to be provided to various tools or loads at some distance from the generator, extension cords are normally used. Cables should be sized to allow for distance in length and amperage so that the voltage drop between the generator and point of use (load) is held to a minimum. Use the cable selection chart (Table 6) as a guide for selecting proper extension cable size.

PAGE 16 — DCA85USJ2 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #1 (03/22/11)

Image 16
Contents Model DCA85USJ2 This Manual Must Accompany the Equipment AT ALL TimesProposition 65 Warning Reporting Safety Defects AdministratorTable of Contents DCA-85USJ2 GeneratorParts Ordering Procedures Ordering parts has never been easierSafety Information Safety MessagesGenerator Safety General Safety Always know the location of the nearest Engine Safety Before servicing equipmentFuel Safety Towing Safety Never use fuel as a cleaning agent From fuel vapors or if fuel is spilled on a hot engineElectrical Safety Grounding SafetyPower Cord/Cable Safety Device. All installations should beBattery Safety Environmental SafetySpecifications DCA-85USJ2Dimensions DimensionsInstallation Typical Generator Grounding ApplicationOutdoor Installation Indoor InstallationMounting Generator GroundingGeneral Information Major Components Item noDisplay Parameters Diagnostic DisplayMenu Button Press this button to enter or exit menu screens Main Menu Navigation First Time Start UpSelecting a Language Stored Fault Codes Engine Configuration DataFirst Time Start-Up Touch the Menu Button to return to the main menu Auxiliary Gage Fault Faults and WarningDisplay will return to the single or four parameter screen Active Fault Codes Fault CodeBachlight Adjustment Shutdown CodesContrast Adjustment Setup 1-UP Display Select UnitsUSE Defaults Automatic Scan on Select the 4-Up Custom Setup from the 4-Up Setup menu Setup 4-Up DisplayTouch the Enter Button and a list of parameters will appear Utilities information and troubleshooting FunctionsTouch Menu Button to return to the Utilities menu Modbus Setup When fi nished, touch Menu to return to the previous screenData Error Timeout ECU not RespondingCanbus Failure No DataGenerator Control Panel OFFEngine Operating Panel OFFEngine Operating Panel Output Terminal Familiarization Output Terminal Panel FamiliarizationTerminal legs O and Ground are considered bonded grounds Removing the Plastic Face Plate Hard Wire Hookup Panel VAC Gfci ReceptaclesConnecting Loads Over Current RelayThree Phase Load Single Phase LoadLoad Application Generator Outputs Generator Output VoltagesHOW to Read the AC Ammeter and AC Voltage Gauges Generator OUTPUTS/GAUGE ReadingAC Voltmeter Gauge Reading AC Ammeter Gauge ReadingOutput Terminal Panel Connections Uvwo Terminal Output Voltages3Ø-240/139 Uvwo Terminal Output Voltages 3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages3Ø-480/277V Uvwo Terminal Output Voltages 1Ø-240/120V Uvwo Terminal Output VoltagesINSPECTION/SETUP Circuit BreakersLubrication OIL Fuel CheckRefueling Procedure Only use #2 diesel fuel when refuelingCleaning the Radiator AIR Cleaner FAN Belt TensionCoolant ANTIFREEZE/SUMMER COOLANT/ Water Operation in Freezing WeatherBattery Battery Cable InstallationWiring AlternatorGenerator START-UP Procedure Manual Mode Before StartingStarting Starting ManualEngine Speed Switch High Before connecting this generator to any Starting Auto ModeWithout this transfer switch Normal Shutdown Procedure Generator SHUT-DOWN ProceduresEmergency Shutdown Procedure General Inspection AIR Cleaner MaintenanceAir Cleaner with Dust Indicator Fuel Tank Inspection Fuel AdditionAIR Removal Radiator Cleaning Check OIL LevelReplacing Oil Filter Flushing OUT Radiator and Replacing CoolantTrailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Brake Adjustment BrakesHydraulic Surge Brakes ActuatorTire Wear/Inflation TIRES/WHEELS/LUG NutsSuspension Lug Nut Torque Requirements Never use an pneumatic air gun to tighten wheel lug nutsTrailer Wiring Diagram Trailer/Towing Vehicle Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramTroubleshooting Generator Troubleshooting Engine Controller Clean/repair radiator grillAdjust governor actuator Adjust governor controllerSample Parts List Explanation of Code in Remarks ColumnSuggested Spare Parts To 3 unitsGenerator Assy 8101070033 00128100358101611004 8101015003Control BOX Assy M2213001702 M22130017120330000180 0330000280Control BOX Assy M4266600004 060180221833A 0601806653 33B 0601802149Control BOX Assy M3223100004 0027105010M9220100004 0080200007Engine and Radiator Assy M2923200094 R135680RE504836 RE529643Engine and Radiator Assy 0605511395 06055113990603306395 0603306399Output Terminal Assy M3230700003 M9220100304M9220100404 0039316000Battery Assy 0602220199 M9310500014M9103000304 0602220920Muffler Assy M2330101303 0017112030M2333001603 M2333200204Fuel Tank Assy M2363000902 06055050700605501073 0605516090Enclosure 1 Assy M2413002202 M23633007030016910030 0603306797Enclosure 1 Assy M2463200603 34A M2493502104M2463400203 M2423200814Enclosure 2 Assy M3443001902 M3493308603M3443002004 M2443400003Enclosure 2 Assy 29A C9312500004 30A 0030006000M9110100804 M9110100904Rubber Seals Assy 0229201240 02292011300314502550 0229200125Nameplate and Decals Assy M1550000204 M1550002203M2550002603 M2550002613Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help