Multiquip DCA85usJ2 manual Fuel Safety, Towing Safety,  Never use fuel as a cleaning agent

Page 9

SAFETY INFORMATION

FUEL SAFETY

DANGER

DO NOT start the engine near spilled fuel or combustible fl uids. Diesel fuel is extremely fl ammable and its vapors can cause an explosion if ignited.

ALWAYS refuel in a well-ventilated area, away from sparks and open fl ames.

ALWAYS use extreme caution when working with flammable liquids.

DO NOT fi ll the fuel tank while the engine is running or hot.

DO NOT overfi ll tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system.

Store fuel in appropriate containers, in well-ventilated areas and away from sparks and fl ames.

NEVER use fuel as a cleaning agent.

DO NOT smoke around or near the equipment. Fire or explosion could result

from fuel vapors or if fuel is spilled on a hot engine.

TOWING SAFETY

CAUTION

Check with your local county or state safety

towing regulations, in addition to meeting

Department of Transportation (DOT) SafetyTowing Regulations, before towing your generator.

Refer to MQ Power trailer manual for additional safety information.

In order to reduce the possibility of an accident while transporting the generator on public roads, ALWAYS make sure the trailer that supports the generator and the towing vehicle are mechanically sound and in good operating condition.

ALWAYS shutdown engine before transporting

Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer “gross vehicle weight rating.”

ALWAYS inspect the hitch and coupling for wear. NEVER tow a trailer with defective hitches, couplings, chains, etc.

Check the tire air pressure on both towing vehicle and trailer. Trailer tires should be inflated to 50 psi cold. Also check the tire tread wear on both vehicles.

ALWAYS make sure the trailer is equipped with a safety chain.

ALWAYS properly attach trailer’s safety chains to towing vehicle.

ALWAYS make sure the vehicle and trailer directional, backup, brake and trailer lights are connected and working properly.

DOT Requirements include the following:

Connect and test electric brake operation.

Secure portable power cables in cable tray with tie wraps.

The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

Avoid sudden stops and starts.This can cause skidding, or jack-knifi ng. Smooth, gradual starts and stops will improve towing.

Avoid sharp turns to prevent rolling.

Trailer should be adjusted to a level position at all times when towing.

Raise and lock trailer wheel stand in up position when towing.

Place chock blocks underneath wheel to prevent rolling while parked.

Place support blocks underneath the trailer’s bumper to prevent tipping while parked.

Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.

DCA85USJ2 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #1 (03/22/11) — PAGE 9

Image 9
Contents This Manual Must Accompany the Equipment AT ALL Times Model DCA85USJ2Proposition 65 Warning Administrator Reporting Safety DefectsDCA-85USJ2 Generator Table of ContentsOrdering parts has never been easier Parts Ordering ProceduresSafety Messages Safety InformationGeneral Safety Generator Safety Always know the location of the nearest Before servicing equipment Engine SafetyTowing Safety Fuel Safety Never use fuel as a cleaning agent From fuel vapors or if fuel is spilled on a hot engineGrounding Safety Electrical SafetyPower Cord/Cable Safety Device. All installations should beEnvironmental Safety Battery SafetyDCA-85USJ2 SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationIndoor Installation Outdoor InstallationMounting Generator GroundingGeneral Information Item no Major ComponentsDiagnostic Display Display ParametersMenu Button Press this button to enter or exit menu screens First Time Start Up Main Menu NavigationSelecting a Language Engine Configuration Data Stored Fault CodesFirst Time Start-Up Touch the Menu Button to return to the main menu Faults and Warning Auxiliary Gage FaultDisplay will return to the single or four parameter screen Fault Code Active Fault CodesShutdown Codes Bachlight AdjustmentContrast Adjustment Select Units Setup 1-UP DisplayUSE Defaults Automatic Scan on Setup 4-Up Display Select the 4-Up Custom Setup from the 4-Up Setup menuTouch the Enter Button and a list of parameters will appear Functions Utilities information and troubleshootingTouch Menu Button to return to the Utilities menu When fi nished, touch Menu to return to the previous screen Modbus SetupTimeout ECU not Responding Data ErrorCanbus Failure No DataOFF Generator Control PanelOFF Engine Operating PanelEngine Operating Panel Output Terminal Panel Familiarization Output Terminal FamiliarizationTerminal legs O and Ground are considered bonded grounds VAC Gfci Receptacles Removing the Plastic Face Plate Hard Wire Hookup PanelOver Current Relay Connecting LoadsSingle Phase Load Three Phase LoadLoad Application Generator Output Voltages Generator OutputsGenerator OUTPUTS/GAUGE Reading HOW to Read the AC Ammeter and AC Voltage GaugesAC Voltmeter Gauge Reading AC Ammeter Gauge ReadingUvwo Terminal Output Voltages Output Terminal Panel Connections3Ø-240/139 Uvwo Terminal Output Voltages 3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages1Ø-240/120V Uvwo Terminal Output Voltages 3Ø-480/277V Uvwo Terminal Output VoltagesCircuit Breakers INSPECTION/SETUPLubrication OIL Fuel CheckOnly use #2 diesel fuel when refueling Refueling ProcedureAIR Cleaner FAN Belt Tension Cleaning the RadiatorCoolant ANTIFREEZE/SUMMER COOLANT/ Water Operation in Freezing WeatherBattery Cable Installation BatteryWiring AlternatorBefore Starting Generator START-UP Procedure Manual ModeStarting Starting ManualEngine Speed Switch High Starting Auto Mode Before connecting this generator to anyWithout this transfer switch Generator SHUT-DOWN Procedures Normal Shutdown ProcedureEmergency Shutdown Procedure Maintenance General Inspection AIR CleanerAir Cleaner with Dust Indicator Fuel Addition Fuel Tank InspectionAIR Removal Check OIL Level Radiator CleaningReplacing Oil Filter Flushing OUT Radiator and Replacing CoolantTrailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Brakes Brake AdjustmentHydraulic Surge Brakes ActuatorTIRES/WHEELS/LUG Nuts Tire Wear/InflationSuspension Never use an pneumatic air gun to tighten wheel lug nuts Lug Nut Torque RequirementsTrailer/Towing Vehicle Wiring Diagram Trailer Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramTroubleshooting Generator Clean/repair radiator grill Troubleshooting Engine ControllerAdjust governor actuator Adjust governor controllerExplanation of Code in Remarks Column Sample Parts ListTo 3 units Suggested Spare PartsGenerator Assy 0012810035 81010700338101611004 8101015003Control BOX Assy M2213001712 M22130017020330000180 0330000280Control BOX Assy 0601802218 M426660000433A 0601806653 33B 0601802149Control BOX Assy 0027105010 M3223100004M9220100004 0080200007Engine and Radiator Assy R135680 M2923200094RE504836 RE529643Engine and Radiator Assy 0605511399 06055113950603306395 0603306399Output Terminal Assy M9220100304 M3230700003M9220100404 0039316000Battery Assy M9310500014 0602220199M9103000304 0602220920Muffler Assy 0017112030 M2330101303M2333001603 M2333200204Fuel Tank Assy 0605505070 M23630009020605501073 0605516090Enclosure 1 Assy M2363300703 M24130022020016910030 0603306797Enclosure 1 Assy 34A M2493502104 M2463200603M2463400203 M2423200814Enclosure 2 Assy M3493308603 M3443001902M3443002004 M2443400003Enclosure 2 Assy 30A 0030006000 29A C9312500004M9110100804 M9110100904Rubber Seals Assy 0229201130 02292012400314502550 0229200125Nameplate and Decals Assy M1550002203 M1550000204M2550002603 M2550002613Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help