Configurator MPK Devices
5−126 CM 4000 Installation and Operating Manual
CP 3830 DUAL CONFIGURATION
Dedicated Output Panel
Dual CP 3830 panels can be configured so that the second panel is always used for output selection. The output panel’s buttons
will glow amber.
MPK bus
CP 3830
“CP3830IN” CP 3830
“CP3830OU”
Dedicated
output panel
Figure 5−100.
CM 4000
“CM1”
CP3830IN CP−3830 200000042
CP3830OU CP−3830 2 00000043
1
MPK Devices
MPK Expansion Pass Board
CM1
Port Address Input Sets Output Sets Level Set Overide Set Sequence Set
2 CM1
KXYZ−INP
KXYZ−OUT KXYZ−LEV
Devices word In Panel Out Panel
KXYZ−LEVKXYZ−OUT
Figure 5−101. Entry for system shown in Figure 5−100.
CP3830IN
Device
Type
CP3830IN
Do the following to connect two CP 3830 panels together with one being an input panel and the other being an output panel:
1. The Expansion box must be unchecked for both the input and output CP 3830.
2. The Output Set should be the same for both panels. The compiler requires the LEV SET field to be defined.
The CP 3830 input panel can be independent of the output CP 3830. The output CP 3830 can still change the output
for the input CP 3830 by selecting the new output name and doing a TAKE.
3. The CP 3830 that is defined as the output panel must have the name of the associated CP 3830 selected in the “In Panel”
field (e.g., CP−3830IN).