Configurator Machine Control Table5−146 CM 4000 Installation and Operating ManualDEFAULT (SEMI−PERMANENT) LINKAGEUsing the file server, machines can be linked directly to a specific control panel on a semi−permanent basis. An example sys-tem is shown in Figure 5−124. In this arrangement, only the file server can re−assign control of a machine to another panel.In other words, the normal linkage function (where machine control follows the routing switcher) is bypassed. The entriesneeded on the Machine Control table are shown in Figure 5−125.
“VT01”
“VC01”
“VC02”
“TAPEMC”
MC−3000
VC02VC01VT01
SELECT buttons
control lines
software links established
by file server Figure 5−124. Default machine control linkage.
312 6
Serial Ports
CM 4000 System Controller “CM1”

Figure 5−125. Default linkage entries

for system shown in Figure 5−124.

1
Machine Control
Device Name Device Type Delegation In/Out Associated
2
TAPEMC MC−3000E Def VT01
3
Mnemonic
TAPEMC
VT01 Sony Mch In
VC01 Sony Mch In
VC02 Sony Mch In
4
Group Name
VT01
VC01
VC02
TAPEMC MC−3000E Def VC01TAPEMC5
TAPEMC MC−3000E Def VC02TAPEMC6