Control Panel Operation
CP 3810
6−129CM 4000 Installation and Operating Manual
SINGLE−BUS CONTROL
In the example shown in Figure 6−159, a CP 3832 is used to select inputs and a “CP 3810L” is used to control the individual
levels of one output. The CP 3810 can thus be used for breakaway switching.
To find out what output is being controlled by the CP 3810, use the “show destination” procedure for the Main panel. In the
example shown in Figure 6−159, the CP 3832 MENU button would be pressed.
Note: To verify that the CP 3810 has been configured as a “CP 3810L,” press the DEST button. This will display
level names if the panel has been configured as a CP 3810L.
Switching Procedure
PRESET OFF method. See Figure 6−159.
Figure 6−159. Switching with Preset OFF.
Select level(s)
(If no levels are
selected, all levels
will switch.)
PRESET OFF
Select source
32
sources
Levels for 1
destination
[1]
[2] [3]
PRESET ON method. See Figure 6−160.
Figure 6−160. Switching
with PRESET ON.
PRESET ON
Press TAKE
Select a
single level
(If no levels
are selected,
all levels will
switch.)
Select a source
If desired,select
another level and source
[1]
[2]
[3]