Software Control Panel Suite
7−4 CM 4000 Installation and Operating Manual
MPK DEVICES TABLE
MPK Devices
1
Dev Name Dev Type Exp PW Board Port Address Inp Set Out Set Lev Set Over Set Seq Set
2
PC1MC2 PC1 1 23232323
MC−3000
3
PC1MC3 PC1 1 45454545
MC−3000
4
PC1MC4 PC1 1 67676767
MC−3000
5
PC1MC5 PC1 1 89898989
MC−3000
6
PC1MC6 PC1 1 90909090
MC−3000
N
N
N
N
N
3800 VM1 6 00C19E22
CP−3800
PC1MC1 PC1 1 01010101
MC−3000
N
N
3800INP 3800OUT 3800LEV
7
Figure 7−3.
Dev Name There must be an entry for at least one CP 3xxx control panel that is capable of machine con-
trol and that has Input, Output, and Level Sets assigned. (This is true even if no physical panel actually
exists.) A CP 3800 panel is shown in this example.
You must also create a name for each of the six Slaved Machine Control panels.
Dev Type For the slaved machine control panels, select “MC−3000.”
Exp For the software machine control panels the entry is always “N.”
Board For the slaved machine control panels, enter the name of the PC that will display the software
panels; this must agree with the PC’s Board Name entered on the Network Description table (page
7−2).
Port For the slaved machine control panels, there must be an entry in each of these fields to satisfy
the compiler.
Address For the slaved machine control panels, there must be a unique entry in each of these fields to
satisfy the compiler.
Inp Set Out Set Lev Set These fields are the source for the set names that appear on the Panel Config-
uration screen (page 7−7). For the six Slaved Machine Control panel entries, these fields must be blank.