CM 4000 / AccuSwitchG−4 CM 4000 Installation and Operating Manual
T
T
T
T
One segment:
185 m (607 ft) max.
30 nodes max
R
T

Figure G−3. Jupiter 10Base2 LAN

cable lengths

Note 1: The individual sections that make up
the 10Base2 cable (those pieces of cable that
run between adjacent nodes) must be at least
0.5 m (20 inches) long.
Note 2: Hewlett−Packard recommends avoid-
ing cable sections that are multiples of 5 me-
ters. Especially avoid sections with a length
of:
Meters Feet
5 16.4
10 32.8
15 49.2
20 65.6
25 82
Note 3: Grass Valley recommends that each
cable segment be a multiple of 0.5 meter in
length (except for the lengths described in
Note 2).
Note 4: All BNC Tees must be equipped with
insulating covers. See page G−6.
See page G−3 for additional guidelines.
Ungrounded
50−ohm terminator
BNC T
Repeater/bridge=
=
=
See notes
BNC T with insulating
cover must be directly
on panel
Controller board (such as
VM 3000 Control Processor)
Additional
segment
R
File Server
(see page 2−36)
Media converter
or Hub
10/100BaseT
LAN
10Base2
LAN