50 CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS

Figure 41 HDLC Status Screen

HDLC Status

------------

Scc channel numbers

- 3

Work Mode

- normal mode

Transmit enable

- yes

Receive Enable

- yes

Maximum length of rx frame- 1518

press <Enter> to continue...

Change HDLC Work Mode

To change the HDLC loopback mode, use the Change Work Mode Menu. In the HDLC Menu, type 4 and press <Enter>. The options in Figure 42 appear.

Figure 42 Change HDLC Work Mode Menu

Current Working Mode of HDLC: Normal Operation

1.Set Normal Mode

2.Set Internal Loopback Mode

0.Return to Previous Menu

Please enter your choice:

In the Change Work Mode Menu, the current working mode is shown to be one of:

Normal Operation

Normal operation is lack of loopbacks.

Internal Loopback Mode

Setting Internal Loopback Mode

To set internal loopback mode, type 2 and press <Enter>. The message appears:

This action will change the working mode of HDLC!