52 CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
To reject, press <Enter> or type n and press <Enter>. The Management
Menu reappears.
To proceed type y and press <Enter>; the message appears:
The system is going down...
The Operation Mode Selector Menu (Figure44) appears.
Figure44 Operation Mode Selector Menu
If this menu is ignored for 5 seconds, execution from the flash begins and
the messages in Figure45 through Figure 47 appear. This is the default
option F.
Option C is for entering the MAC address. This is normally performed in
the factory.
Option D is for debugging. This option is for developers only.
Option S is for downloading software through the LMA port. For more
information see Appendix C Loading Software Through Local Access.
To use an option, type its letter.
To continue with the reset operation without performing the other
options, do one the followin steps:
Wait 5 seconds.
********************************************************
3Com NCD. (C)
10Base-S Boot loader V2.00
Date: Jun 15 1999, Time: 16:13:31
CPE modem Operation Mode Selector.
Enter: S - for Serial loading OR
D - for Debug operation OR
F - for SW execution from the Flash OR
C - for MAC address programming.
********************************************************