| Starting the Diagnostic Program  | |
Table   | 
  | |
  | ||
  | 
  | 
  | 
Diagnostic Program Name  | Adapter  | 
  | 
  | 
  | 
  | 
3C503  | EtherLink II® or II TP  | 
  | 
  | EtherLink II/16 or II/16 TP  | 
  | 
3C505  | EtherLink Plus®  | 
  | 
3C507  | EtherLink 16 or EtherLink 16 TP  | 
  | 
3C5X9CFG  | EtherLink III family  | 
  | 
3C523  | EtherLink/MC  | 
  | 
3C523TP  | EtherLink/MC TP  | 
  | 
3C527  | EtherLink/MC 32  | 
  | 
3C59XCFG.EXE  | EtherLink III EISA, EtherLink III PCI,  | 
  | 
  | Fast EtherLink PCI, and Fast EtherLink EISA  | |
  | 
  | 
  | 
Starting the Group 3 Test
To run the Group 3 test on a Fast EtherLink EISA adapter, follow these steps:
1Start the Configuration and Diagnostic Program.
This program must be on the computer containing the adapter you want to test.
2Select Test Setup from the Test menu.
3Select Group 3 from the Group Select box.
4Enable the Group 3 test by selecting the Enable Group button.
5Select OK and press [Enter].
6Go to the Run Tests dialog box and select Start to start the tests.
7After the test is completed:
a End the program on the echo server. b Exit the diagnostic program.