3Com EISA 10/100BASE-T manual Running the Group 3 Test, Mbps or 100 Mbps

Models: EISA 10/100BASE-T

1 74
Download 74 pages 59.75 Kb
Page 50
Image 50

Starting the Diagnostic Program

5-5

To run the tests continuously, go to the Repetitions box on the Test Setup screen, and select Continuous (and deselect Halt on Error in the Errors box).

The Group 1 tests include:

Register Access Test

EEPROM Test

FIFO Loopback Test

Ethernet Core Loopback Test

Encoder/Decoder Loopback Test

Interrupt Test

For a description of each Group 1 test, access help by pressing [F1].

Running the Group 3 Test

The Group 3 test is called the Echo Exchange Test. It tests the adapter’s ability to transmit and receive data while on the network.

CAUTION: Running the Group 3 test while connected to an active network can cause intermittent failures. To avoid this, connect to an inactive network on which only the computer being tested and the echo server are operating.

To run the Group 3 test on the network, you need a second computer set up as an echo server. The echo server receives packets from the adapter being tested and echoes them back to the adapter.

The second computer must contain a 3Com adapter running at the same speed as the Fast EtherLink EISA adapter

(10 Mbps or 100 Mbps).

Page 50
Image 50
3Com EISA 10/100BASE-T manual Running the Group 3 Test, Mbps or 100 Mbps