5-10 CHAPTER 5: PERFORMING TROUBLESHOOTING AND DIAGNOSTIC TESTS

3To change a setting in any field, follow these steps:

a In the Group Select box, use the arrow keys to select a test group.

b In the Group X Tests box, use the arrow keys to highlight a test. Press the [Space Bar] to enable or disable an individual test.

c In the Repetitions box, specify the number of times you want to run the tests, or use the arrow keys to select the Continuous option.

d In the Errors box, press the [Space Bar] to select or deselect the Halt on Error parameter.

4When you are satisfied with the new test setup, select the OK button and press [Enter].

5To run the tests, choose Run Tests from the Test menu and select the Start button.

Miscellaneous Checks

Check for specific hardware problems, such as broken traces or loose/broken solder connections.

If you have installed the adapter correctly and you still experience problems, check the software.

Check the length and rating of the UTP cable connection. Make sure the cable segment complies with 10BASE-T or 100BASE-TX recommendations. Maximum length for all types of cabling for this adapter is 100 meters.

Make sure that you have installed the correct driver for the network operating system you are running (refer to Chapter 4, “Loading Network Drivers”).

If any problem persists, refer to Appendix B, “Technical Support.”