Data Addendum

Pressure to free field corrections with QE7052 microphone (sections: 5.2.8, 9.2.7d)

Note: add to pressure response to get 0incidence free-field response. B&K 4226 calibrator may be used to determine the pressure field response.

 

QE7052 microphone

 

Pressure Field to

 

Free Field

Frequency

Corrections

in Hz

in dB

32

0.1

40

-0.1

50

0.0

63

-0.1

80

-0.2

100

-0.3

125

-0.3

160

-0.3

200

0.0

250

0.1

315

0.1

400

0.1

500

0.1

630

0.1

800

0.0

1000

0.0

1250

0.0

1600

0.2

2000

0.4

2500

0.5

3150

0.5

4000

1.3

5000

2.3

6300

4.4

8000

5.0

10000

4.5

12500

5.6

16000

7.9