LTPH-UM-1031-03, Issue 3Testing

Table 15. Front-Panel System Alarms (Continued)

Front-Panel

Alarm

Description

To Inhibit:

Message (a)

 

 

 

RRAI

Remote RAI—Remote

 

Alarm Indication at the

 

H4TU-R (Net signal

 

has errors.)

Indicates an RAI alarm (yellow) from the CPE Cannot be inhibited. with errors from the line unit or network.

xxx-DBER

DS1 Bit Error Rate

The DS1 BER has exceeded the set 24-hour

Select DIS for the DBER system option.

 

 

threshold limit of approximately 10-6. (xxx

 

 

 

denotes either TUC or TUR. If TUC and TUR

 

 

 

occur at the same time, then TUC displays.)

 

 

 

 

 

xxx-LOF

Loss of Frame

The DS1 input does not contain the ESF or SF

Change FRMG option to AUTO or UNFR.

 

 

frame pattern setting of the FRMG option.

 

 

 

(xxx denotes either TUC or TUR. If TUC and

 

 

 

TUR occur at the same time, then TUC

 

 

 

displays.)

 

 

 

 

 

PRMN

Performance Report

H4TU-R PRM-NE BER threshold has been

Set DBER threshold to DIS.

 

Messaging - Near End

exceeded.

 

 

 

 

 

PRMF

Performance Report

H4TU-R PRM-FE BER threshold has been

Set DBER threshold to DIS.

 

Messaging - Far End

exceeded.

 

 

 

 

 

xxxx-HBRx (d)

HDSL4 Block Error

The HDSL4 BER has exceeded the set

Select NONE for the HBER system option.

 

Rate

threshold limits of 10-6or 10- 7.

 

 

 

xxxx denotes TUC, TUR, or first

 

 

 

(DU1U/DU1D) or second (DU2U/DU2D)

 

 

 

doubler HDSL4 upstream or downstream

 

 

 

interface. If TUC and TUR occur at the same

 

 

 

time, then TUC displays. The single x

 

 

 

indicates Loop 1 or Loop 2.

 

 

 

 

 

xxxx-MALx (d)

Margin Alarm

The margin on the HDSL4 loop has dropped

Set the Margin Alarm Threshold option to

 

 

below the minimum threshold value set for the

zero.

 

 

system.

 

 

 

xxxx denotes TUC, TUR, or first

 

 

 

(DU1U/DU1D) or second (DU2U/DU2D)

 

 

 

doubler HDSL4 upstream or downstream

 

 

 

interface. If TUC and TUR occur at the same

 

 

 

time, then TUC displays. The single x

 

 

 

indicates Loop 1 or Loop 2.

 

 

 

 

 

xxxx-LAx (d)

Loop Attenuation

The attenuation on the HDSL4 loop has

Set the HDSL4 Loop Attenuation

 

 

exceeded the maximum value set for the

Threshold option to zero.

 

 

HDSL4 loop attenuation threshold.

 

xxxxdenotes TUC, TUR, or first (DU1U/DU1D) or second (DU2U/DU2D) doubler HDSL4 upstream or downstream interface. If TUC and TUR occur at the same time, then TUC displays. The single x indicates Loop 1 or Loop 2.

(a)The message, ALRM, displays prior to any alarm message.

(b)Message displays repeatedly as long as the alarm condition exists and is not included in the priority order.

(c)When the HDSL4 loop loses sync word (LOSW), a system alarm condition exists. However, since the H4TU-C-319 enters the acquiring mode, the front-panel status LED flashes red, and the ACQ or SIG message displays instead of the ALRM message.

(d)Only these alarms assert the System Alarm bus on pin H of the card-edge connector, if the ALM option is set to enabled.

H4TU-C-319 List 1

September 12, 2003

43