
Front PanelLTPH-UM-1031-03, Issue 3
Table 2. Front-Panel  Display Messages (Continued)
Message | Full Name  | Description  | 
  | 
  | |
LOOPBACK MESSAGES | 
  | |
CDU1 | Customer Doubler 1 Loopback  | DS1 signal from customer is looped back to the customer at H4D1  | 
  | 
  | (111100).  | 
CDU2 | Customer Doubler 2 Loopback  | DS1 signal from customer is looped back to the customer at H4D2  | 
  | 
  | (111110).  | 
CLOC | Customer Local Loopback  | DS1 signal from customer is looped back to the customer at the   | 
COLB  | Central Office Loopback  | Dual loopback at the   | 
CREM  | Customer Remote Loopback  | DS1 signal from customer is looped back to the customer at the  | 
  | 
  | |
NDU1  | Network Doubler 1 Loopback  | Signal is looped back to the network at H4D1 (110000).  | 
NDU2  | Network Doubler 2 Loopback  | Signal is looped back to the network at H4D2 (111000).  | 
NLOC  | Network Local Loopback  | |
NREM  | Network Remote Loopback  | |
RULB  | Remote Unit Loopback  | Dual loopback at the   | 
SMJK | Remote SmartJack Loopback  | |
  | 
  | module.  | 
DIAGNOSTIC MESSAGES | 
  | |
A=xx  | Maximum Loop Attenuation  | The Attenuation (A) message appears followed by xx, where xx is the  | 
  | 
  | highest loop attenuation of all HDSL interfaces.  | 
ACQ1 or ACQ2  | Acquisition 1 or Acquisition 2  | The multiplexers of the   | 
  | 
  | synchronization over HDSL4 Loop 1 or Loop 2.  | 
ARM  | System Armed  | Armed to respond to Intelligent Repeater Loop (ILR) codes.  | 
BAD RT? | No Response from  | The   | 
  | 
  | loop conditions are normal; therefore, the integrity of the   | 
  | 
  | the HDSL4 loops is questionable.  | 
FERR | Framing Bit Error Occurred  | Framing bit error occurred at   | 
HxES  | HDSL4 CRC Error Loop 1 or Loop 2  | |
  | 
  | error. (Loop 1 has display priority over Loop 2.)  | 
LBPV | Local Bipolar Violation  | A bipolar violation has been received at the   | 
  | 
  | |
1=xx or 2=xx | HDSL4 Loop Margin | Indicates the power of the received HDSL4 signal on each loop relative  | 
  | 
  | to noise (S/N with respect to 21.5 dB). Any value of 6 dB or greater is  | 
  | 
  | adequate for reliable system operation. (xx denotes lowest margin in  | 
  | 
  | dB for Loop 1 and Loop 2.)  | 
MNGD | Managed  | The   | 
  | 
  | management unit. In this state, the   | 
  | 
  | pushbuttons are disabled.  | 
PWR FEED OFF | Power Feed Off | HDSL4 span power has been turned off by setting the PWRF option to  | 
  | 
  | OFF, or HDSL4 span power has been turned off by use of the A5LB  | 
  | 
  | Intelligent Office Repeater (IOR) powerdown code.  | 
PWR FEED ON | Power Feed On  | Indicates that the HDSL4 loop power is applied and neither pair is  | 
  | 
  | grounded.  | 
SIG1 or SIG2  | Signaling  | The transceivers of the   | 
  | 
  | contact with each other over HDSL4 on Loop 1 or Loop 2.  | 
SYSTEM INFORMATION MESSAGES (a) | 
  | |
VER x.xx  | Software Version Number  | The software version number of the   | 
LIST xx  | List Number  | The list number of the   | 
  | 
  | 
  | 
  | 
  | Continued  | 
6  | September 12, 2003  |