Front PanelLTPH-UM-1031-03, Issue 3

Table 2. Front-Panel Display Messages (Continued)

Message

Full Name

Description

 

 

LOOPBACK MESSAGES

 

CDU1

Customer Doubler 1 Loopback

DS1 signal from customer is looped back to the customer at H4D1

 

 

(111100).

CDU2

Customer Doubler 2 Loopback

DS1 signal from customer is looped back to the customer at H4D2

 

 

(111110).

CLOC

Customer Local Loopback

DS1 signal from customer is looped back to the customer at the H4TU-R.

COLB

Central Office Loopback

Dual loopback at the H4TU-C.

CREM

Customer Remote Loopback

DS1 signal from customer is looped back to the customer at the

 

 

H4TU-C.

NDU1

Network Doubler 1 Loopback

Signal is looped back to the network at H4D1 (110000).

NDU2

Network Doubler 2 Loopback

Signal is looped back to the network at H4D2 (111000).

NLOC

Network Local Loopback

DSX-1 signal is looped back to the network at the H4TU-C.

NREM

Network Remote Loopback

DSX-1 signal is looped back to the network at the H4TU-R.

RULB

Remote Unit Loopback

Dual loopback at the H4TU-R.

SMJK

Remote SmartJack Loopback

DSX-1 signal is looped back to the network at the H4TU-R SmartJack

 

 

module.

DIAGNOSTIC MESSAGES

 

A=xx

Maximum Loop Attenuation

The Attenuation (A) message appears followed by xx, where xx is the

 

 

highest loop attenuation of all HDSL interfaces.

ACQ1 or ACQ2

Acquisition 1 or Acquisition 2

The multiplexers of the H4TU-C and H4TU-R are trying to establish

 

 

synchronization over HDSL4 Loop 1 or Loop 2.

ARM

System Armed

Armed to respond to Intelligent Repeater Loop (ILR) codes.

BAD RT?

No Response from H4TU-R

The H4TU-C receives no response from the H4TU-R, and all HDSL4

 

 

loop conditions are normal; therefore, the integrity of the H4TU-R or

 

 

the HDSL4 loops is questionable.

FERR

Framing Bit Error Occurred

Framing bit error occurred at H4TU-C DSX-1 input.

HxES

HDSL4 CRC Error Loop 1 or Loop 2

H4TU-C HDSL4 Loop 1 or Loop 2 Cyclical Redundancy Check (CRC)

 

 

error. (Loop 1 has display priority over Loop 2.)

LBPV

Local Bipolar Violation

A bipolar violation has been received at the DSX-1 input to the

 

 

H4TU-C-319.

1=xx or 2=xx

HDSL4 Loop Margin

Indicates the power of the received HDSL4 signal on each loop relative

 

 

to noise (S/N with respect to 21.5 dB). Any value of 6 dB or greater is

 

 

adequate for reliable system operation. (xx denotes lowest margin in

 

 

dB for Loop 1 and Loop 2.)

MNGD

Managed

The H4TU-C-319 is under control of the HMU-319 network

 

 

management unit. In this state, the front-panel craft port and

 

 

pushbuttons are disabled.

PWR FEED OFF

Power Feed Off

HDSL4 span power has been turned off by setting the PWRF option to

 

 

OFF, or HDSL4 span power has been turned off by use of the A5LB

 

 

Intelligent Office Repeater (IOR) powerdown code.

PWR FEED ON

Power Feed On

Indicates that the HDSL4 loop power is applied and neither pair is

 

 

grounded.

SIG1 or SIG2

Signaling

The transceivers of the H4TU-C and H4TU-R are trying to establish

 

 

contact with each other over HDSL4 on Loop 1 or Loop 2.

SYSTEM INFORMATION MESSAGES (a)

 

VER x.xx

Software Version Number

The software version number of the H4TU-C-319.

LIST xx

List Number

The list number of the H4TU-C-319.

 

 

 

 

 

Continued

6

September 12, 2003

H4TU-C-319 List 1

Page 14
Image 14
ADC HDSL4, H4TU-C-319 List 1 Line Unit user manual Loopback Messages, Diagnostic Messages, System Information Messages a