LTPH-UM-1031-03, Issue 3Monitoring System Activity and Performance

 

Table 8. Monitor Screen Descriptions (Continued)

 

 

Field

Description

 

 

UAS Count

Unavailable Seconds—The number of seconds during which the DS1 input signal was absent over

 

a 24-hour period.

 

 

Frame and Code Type

 

ESF

Type of DS1 framing used on the input stream (SF, ESF, or UNFR).

B8ZS

Type of DS1 line coding used (B8ZS or AMI).

 

 

HDSL4 Errors

 

ES Count

Errored Seconds—The number of 1-second intervals that contained at least one CRC or LOSW

 

error. This value is a running total of the last 24 Hours.

SES Count

Severely Errored Seconds—The number of 1-second intervals that contain at least 50 CRC errors

 

or one or more LOSW defects. (An LOSW defect occurs when at least three consecutive HDSL

 

frames contain one or more frame bit errors.) This value is a running total of the last 24 hours.

UAS Count

Unavailable Seconds—The number of seconds the HDSL4 loop is unavailable. This occurs after

 

10 contiguous HDSL SES and is retired after 10 contiguous non-SES seconds. This value is a

 

running total of the last 24 hours.

 

 

ID

Circuit identification number.

 

 

INSL

Insertion Loss—The signal loss value for a 196 kHz signal over the cable pair.

 

 

LA

Loop Attenuation—Indicates the attenuation of the Overlapped Pulse Amplitude Modulation

 

(OPAM) transmission pulse from the distant end. Proper HDSL4 loop operation requires that this

 

value be less than 34 dB. This value differs from the insertion loss value of a conventional 196 kHz

 

signal.

 

 

LPF

Line Power Feed—Indicates the HDSL4 line power is on.

 

 

M

Margin—The signal-to-noise ratio at all HDSL4 ports, relative to a 10-7Bit Error Rate.

PL (or HG)

PL displays when the loopback was initiated by a command embedded in the DS1 data path

 

payload (PL). HG displays when the loopback was initiated from a HDSL Generic (HG) front panel

 

or by a maintenance terminal loopback command.

 

 

PRM

The sum of the Performance Report Messaging-Near End (PRM-NE) and Performance Report

 

Messaging-Far End (PRM-FE) counts.

 

 

System Status

The presence or absence of an alarm condition is indicated on the lower right corner of all screens.

 

System: OK indicates that there are no alarms present; System: Alarm indicates the presence of an

 

alarm. Refer to “Using the Performance Screens to View Alarm Data” on page 35.

 

 

H4TU-C-319 List 1

September 12, 2003

27

Page 35
Image 35
ADC H4TU-C-319 List 1 Line Unit, HDSL4 user manual Insl, Lpf, Prm