LTPH-UM-1031-03, Issue 3

Monitoring System Activity and Performance

 

 

Table 13. Event Log Entry Messages List

Event Log Messages

HDSL4 DC pair open begins/ends on any segment

HDSL4 Ground fault begins/ends on any segment

H4TU-C Power up/down

H4TU-R Power up/down

HDSL4 margin alarm (threshold crossed) on any HDSL4 Interface (I/F)

HDSL4 loop attenuation (threshold crossed) on any HDSL4 I/F

HDSL4 HBER alarm (threshold crossed) on any HDSL4 I/F

HDSL4 LOSW begins/ends on any segment

CPE DBER alarm (1-day threshold of any PM data crossed—except PRM-NE or

PRM-FE)

CPE PRM-NE BER alarm (at the remote only: 1-day PRM-NE threshold crossed: trouble on CPE receive)

NTWK PRM-FE BER alarm (at the remote only: 1-day PRM-FE threshold

crossed: trouble on NTWK far end)

NTWK DBER alarm (1-day threshold of any PM data crossed)

CPE DS1 LOS begins/ends

CPE DS1 AIS begins/ends

NTWK DS1 LOS begins/ends

NTWK DS1 AIS begins/ends

TX RAI-CI begins/ends (RAI-CI sent from the remote towards the network)

RAI begins/ends

Any HDSL4 PM register reset

Any DS1 PM register reset

Any DS1 Alarm History reset

Any HDSL4 Alarm History reset

Event Log reset

Current statistics reset

Master zero reset

Any provisioning option change: <provisioning mnemonic>: changed from <old> to <new>

Any Loop Up (any segment)

Any Loop Down (any segment)

Power Feed Short begins / ends

H4TU-C-319 List 1

September 12, 2003

39

Page 47
Image 47
ADC H4TU-C-319 List 1 Line Unit, HDSL4 user manual Event Log Entry Messages List, Event Log Messages, Prm-Fe