Installation

LTPH-UM-1031-03, Issue 3

 

 

INSTALLATION

Upon receipt of the equipment, inspect the contents for signs of damage. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company and to ADC.

H4TU-C-319

CO shelf

Figure 2. Installing the H4TU-C-319 List 1 into a Shelf

When installing an H4TU-C in a chassis, be sure to wear an antistatic wrist strap. Avoid touching components on the circuit board.

To comply with the intrabuilding wiring requirements of GR-1089 CORE, Section 4.5.9, the shields of the ABAM-type cables that connect the H4TU-C DSX-1 output ports to the cross-connect panel must be grounded at both ends.

1Align the H4TU-C with the enclosure slot guides, then push the unit in until it touches the backplane card-edge connector.

2Place your thumbs on the front panel and push the H4TU-C into the slot guides until properly seated.

8

September 12, 2003

H4TU-C-319 List 1

Page 16
Image 16
ADC HDSL4, H4TU-C-319 List 1 Line Unit user manual Installation, Installing the H4TU-C-319 List 1 into a Shelf