LTPH-UM-1031-03, Issue 3

Monitoring System Activity and Performance

 

 

USING THE PERFORMANCE SCREENS TO VIEW ALARM DATA

To access the alarm history screens:

1Press P to select the Performance screen.

2Press the SPACEBAR to select an interface (H4TU-C DS1, H4TU-R DS1, H4TU-C HDSL, H4DU-1 NET HDSL, H4DU-1 CPE HDSL, H4DU-2 NET HDSL, H4DU-2 CPE HDSL, or H4TU-R HDSL), then press

ENTER .

3Press the SPACEBAR until Alarm History is selected, then press ENTER . (To clear the selected alarm history screen, press L .)

Alarm History at the DS1 Interface

The Alarm History screen reports DS1 statistics for the H4TU-C (Figure 22) and the H4TU-R (Figure 23 on page 36) on a continuous basis. The types of alarms reported are described in Table 11 on page 36. Current alarms are shown in reverse video.

Monitor

 

Performance

Event Log

Config

Inventory Report Rlogon

Help

 

 

 

H4TU-C DS1

Alarm

History

 

-----------------------------------------------------------------------------

Alarm

First

Last

Status

Count

LLOS

01/30/02

 

ALARM

12

LAIS

 

 

OK

0

DBER

01/30/02

 

OK

7

LOF

 

OK

0

Press: C(l)ear Alarm History

-----------------------------------------------------------------------------

Use <Space>

to cycle through

Interface :

H4TU-C DS1

 

choices and

<Enter> to view

Statistics :

Alarm History

 

ID: xxxx--

xxxx--xxxx—-xxxx

02/01/2002 12:30:01

H4TU-C

System: Alarm

Figure 22. H4TU-C DS1 Alarm History Screen

H4TU-C-319 List 1

September 12, 2003

35

Page 43
Image 43
ADC H4TU-C-319 List 1 Line Unit Using the Performance Screens to View Alarm Data, Alarm History at the DS1 Interface