LTPH-UM-1031-03, Issue 3

Monitoring System Activity and Performance

 

 

Alarm History at the HDSL4 Interface

The HDSL4 Alarm History screens report alarms for the HDSL4 interface at the H4TU-C and H4TU-R. Figure 24 shows the H4TU-C HDSL4 alarm history. Table 12 describes the alarms that are reported at the H4TU-C or H4TU-R.

Monitor

 

Performance

Event Log Config

Inventory Report Rlogon

Help

 

 

 

H4TU-C HDSL

Alarm History

 

-----------------------------------------------------------------------------

Alarm

First

Last

Status

Count

LOSW-LP1

01/15/02 16:45

01/15/02 16:45

OK

1

MAL

-LP1

01/15/02 16:44

01/15/02 16:44

OK

1

LA

-LP1

 

 

OK

0

HBER-LP1

01/15/02 16:45

01/15/02 16:45

DISABLED

0

LOSW-LP2

OK

1

MAL

-LP2

 

 

OK

0

LA

-LP2

 

 

OK

0

HBER-LP2

 

 

DISABLED

0

SHORT

 

 

OK

0

GND

 

 

 

OK

0

OPEN

 

 

 

OK

0

Press: C(l)ear Alarm History-

-----------------------------------------------------------------------------

Use <Space>

to cycle through

Interface :

H4TU-C HDSL

 

choices and

<Enter> to

view

Statistics :

Alarm History

 

ID: xxxx--

xxxx--xxxx--

xxxx

02/01/2002 12:30:01

H4TU-C

System: Alarm

Figure 24. H4TU-C HDSL Alarm History Screen

 

 

Table 12. HDSL4 Alarm Descriptions

 

 

 

Screen Alarm

Front-Panel Alarm

Description

 

HDSL4 Alarms at the H4TU-C and H4TU-R

 

 

 

LOSW

SPNn-LOSW

Loss of Sync Word—The HDSL4 loop has lost synchronization.

MAL

xxxx-MALx

Margin—The margin on the HDSL4 loop has dropped below the minimum threshold

 

 

value set for the system.

 

 

xxxx denotes TUC, TUR, or first (DU1U/DU1D) or second (DU2U/DU2D) doubler HDSL4

 

 

upstream or downstream interface. If TUC and TUR occur at the same time, then TUC

 

 

displays. The single x indicates Loop 1 or Loop 2.

LA

xxxx-LAx

Loop Attenuation—The attenuation on the HDSL4 loop has exceeded the maximum value

 

 

set for the HDSL4 loop attenuation threshold.

 

 

xxxx denotes TUC, TUR, or first (DU1U/DU1D) or second (DU2U/DU2D) doubler HDSL4

 

 

upstream or downstream interface. If TUC and TUR occur at the same time, then TUC

 

 

displays. The single x indicates Loop 1 or Loop 2.

HBER

xxxx-HBRx

Block Error Rate—The HDSL4 BER has exceeded the set threshold limits of 10-6or 10- 7.

 

 

xxxx denotes TUC, TUR, or first (DU1U/DU1D) or second (DU2U/DU2D) doubler HDSL4

 

 

upstream or downstream interface. If TUC and TUR occur at the same time, then TUC

 

 

displays. The single x indicates Loop 1 or Loop 2.

 

 

 

HDSL4 Alarms at the H4TU-C only

SHORT (a)

PWR FEED SHRT

Indicates a short between Loop 1 and Loop 2 of the HDSL4 pair.

GND (a)

PWR FEED GND

One of the HDSL4 loops is grounded.

OPEN (a)

PWR FEED OPEN

Indicates a line power open condition.

(a) Displays only at the H4TU-C HDSL interface.

H4TU-C-319 List 1

September 12, 2003

37

Page 45
Image 45
ADC H4TU-C-319 List 1 Line Unit user manual Alarm History at the HDSL4 Interface, HDSL4 Alarms at the H4TU-C only