Testing

LTPH-UM-1031-03, Issue 3

 

 

TESTING

This section provides information about front-panel system alarms, LOS and AIS response, the OCT55 test procedure, and loopback testing.

SYSTEM ALARMS

Table 15 summarizes all possible system alarms in order of priority as they appear on the front panel. When multiple alarms occur, the front-panel display only reports the highest priority alarm. The alarm history screens display alarms also, but provide greater detail (see “Using the Performance Screens to View Performance Data” on page 28). Alarms that are not inhibited will drive the front-panel Status LED to a flashing red alarm state.

Table 15. Front-Panel System Alarms

Front-Panel

Alarm

Description

To Inhibit:

Message (a)

 

 

 

PWR FEED

Power Feed Short

A short exists between Loop 1 and Loop 2 of

Cannot be inhibited.

SHRT (b)

 

the HDSL4 pair.

 

PWR FEED

Power Feed Ground

One of the HDSL4 loops is grounded.

Cannot be inhibited.

GND (b)

 

 

 

PWR FEED

Power Feed Open

A line power open condition exists.

Cannot be inhibited.

OPEN (b)

 

 

 

SPNn-LOSW

Span(n)-Loss of Sync

The HDSL4 loop has lost synchronization.

Cannot be inhibited.

 

Word (c)

The span closest to the network has highest

 

 

 

priority.

 

 

 

 

 

LLOS

Line (Unit) Loss of

Loss of the DSX-1 input signal.

Cannot be inhibited.

 

Signal

 

 

 

 

 

 

RLOS

Remote (Unit) Loss of

Loss of the H4TU-R DS1 input signal.

Disable the RDA (Remote Disconnect

 

Signal

 

Alarm) option. This prevents an LOS

 

 

 

condition at the DS1 input to a H4TU-R

 

 

 

from activating pin H. The front-panel

 

 

 

Status LED still flashes red and the ALRM

 

 

 

RLOS message displays to alert you of the

 

 

 

LOS state. LOS is sent towards the

 

 

 

network from the H4TU-C. This option

 

 

 

prevents the common occurrences of a

 

 

 

CPE LOS condition from generating

 

 

 

recurring alarms and AIS payloads.

 

 

 

 

LAIS

Line Alarm Indication

Indicates an AIS (unframed all ones) pattern

Cannot be inhibited.

 

Signal

is being received at the H4TU-C DS1 input

 

 

 

port.

 

 

 

 

 

RAIS

Remote Alarm

Indicates an AIS (unframed all ones) pattern

Cannot be inhibited.

 

Indication Signal

is being received at the H4TU-R DS1 input

 

 

 

port.

 

 

 

 

 

LRAI

Line RAI—Remote

 

Alarm Indication at the

 

H4TU-R (Net signal

 

does not have errors.)

Indicates an RAI alarm (yellow) from the CPE Cannot be inhibited. with an error-free signal from the line unit or

network. RAI signal is transmitted towards the network.

Continued

42

September 12, 2003

H4TU-C-319 List 1

Page 50
Image 50
ADC HDSL4 user manual Testing, Front-Panel System Alarms, Front-Panel Alarm Description To Inhibit Message a, PWR Feed