LTPH-UM-1031-03, Issue 3

Testing

 

 

The Time-Out Override function is only valid for the current active loopback. The automatic time-out timer is restored during subsequent loopback sessions.

5Once the test is complete, do one of the following:

If the system is to loopdown but remain armed, send the IR (Intelligent Repeater) LPDN code (universal loopdown).

If all the equipment is to be looped down, disarmed and returned to normal operation, send the disarm inband code 11100 or the ESF-DL code (FF24).

The Armed mode has an automatic time-out of 120 minutes, but this timer is reset to 120 for any of the following events:

Loopback terminates (manually or time-out)

Query

Alternate query

Far End activate

Another ARM command

This timer is inhibited while any of the valid command codes are being sent. Once the codes are removed, the timer restarts at 120.

H4TU-C-319 List 1

September 12, 2003

55

Page 63
Image 63
ADC H4TU-C-319 List 1 Line Unit, HDSL4 user manual LTPH-UM-1031-03, Issue