Testing

LTPH-UM-1031-03, Issue 3

 

 

TESTING WITH H4TU-C BERT GENERATOR

The H4TU-C BERT Generator screen allows transmission of an unframed test signal from the H4TU-C toward either the CI or the network.

It is not recommended using the Bit Error Rate Tester from the remote and line unit at the same time.

1Press C to select the Config menu (Figure 30).

2Use the and arrow keys to select BERT Generator, then press ENTER .

3Use the arrow keys to select an option and press the SPACEBAR to cycle through the settings. Refer to Table 19 for a list of BERT generator option settings.

4Press ENTER to activate your choice.

5To view BERT status, press ESC twice, then use the arrow key to select the Monitor menu.

6Press ENTER . You can exit the status screen while signal generation is active.

Monitor

Performance Event Log

Config

Inventory

Report Rlogon

Help

 

----------------------+

 

 

+

 

 

 

Standard Options

->

 

 

 

 

ADC Options

->

 

 

 

 

BERT Generator

->

 

 

+--------------------------------------

 

 

+

BERT Signal Generator

:

ENA

 

BERT Signal Pattern

:

1 in 8

BERT Signal Linecode

: AMI

BERT Signal Direction

: NET only

BERT Interval

: Continuous

+--------------------------------------

 

 

+

Use <Spacebar> to cycle through option settings and

<Enter> to activate

 

ID: xxxx—-xxxx—-xxxx--xxxx

02/01/2002 12:30:01

H4TU-C

System:

OK___

 

Figure 30. H4TU-C BERT Generator Screen

 

 

 

 

Table 19. BERT Signal Generator Option Settings

 

 

 

 

 

 

 

 

 

 

 

Option

Description

 

 

 

 

 

 

 

 

 

 

 

 

BERT Signal Generator

Enabled (ENA) or Disabled (DIS)

 

 

 

 

 

BERT Signal Pattern

1-in-8 pattern, 2-in-8 pattern, 3-in-24 pattern, 223-1pseudo random,

 

 

220-1pseudo random, 215-1pseudo random

 

 

 

 

BERT Signal Linecode

AMI or B8ZS

 

 

 

 

 

BERT Signal Direction

Toward CPE or toward NET

 

 

 

 

 

BERT Interval

5 minutes, 60 minutes, Continuous (default)

 

 

 

 

 

 

 

 

 

 

 

56