ProvisioningLTPH-UM-1031-03, Issue 3

Table 5. H4TU-C-319 List 1 Standard Config Menu Options (Continued)

Standard Config

Screen

Selection

Description

Menu Options

Display Code

 

 

 

 

 

 

H4TU-R TLOS

TLOS

ENA

Enables a logic loopback at the H4TU-R when an LOS occurs at its DS1 input.

Loopback

 

 

For priority resolution, see Figure 27 on page 45.

 

 

DIS

Disables TLOS logic loopback.

 

 

 

 

Network Loopback

NLBP

AIS

Enables the H4TU-R to transmit AIS towards the CI for any network loopback.

Pattern

 

 

For priority resolution, see Figure 27 on page 45.

 

 

LOS

Enables the H4TU-R to transmit LOS towards the CI for any network

 

 

 

loopback.

Power Back Off -

PBON

Network

 

See “Power Back Off

 

(PBON and PBOC)

 

Options” on page 22.

 

DEF

Configures the power output levels of the H4TU-C network unit toward the

 

customer to comply with the Default template as defined in Section 6.1.4.2 of

 

ANSI T1.418.

ENH

Configures the power output levels of the H4TU-C network unit toward the

 

customer to comply with the Enhanced template as defined in Section 6.1.4.2

 

of ANSI T1.418.

Power Back Off -

PBOC

Customer

 

See “Power Back Off

 

(PBON and PBOC)

 

Options” on page 22.

 

DEF

Configures the power output levels of the H4TU-R customer unit toward the

 

network to comply with the Default template as defined in Section 6.1.4.2 of

 

ANSI T1.418.

ENH

Configures the power output levels of the H4TU-R customer unit toward the

 

network to comply with the Enhanced template as defined in Section 6.1.4.2

 

of ANSI T1.418.

Table 6. H4TU-C-319 List 1 ADC Config Menu Options

ADC Config Menu

Screen

Selection

Description

Options

Display Code

 

 

 

 

Line Power Feed

PWRF

OFF

Disables powering to the HDSL4 pair.

 

 

LOW

Keeps the HDSL4 line voltage at nominal -185 Vdc.

 

 

HIGH

Keeps the HDSL4 line voltage at nominal ±123 Vdc.

 

 

AUTO

Keeps the H4TU-C line voltage at -185 Vdc when line powering up to two

 

 

 

devices (one doubler and one remote unit, or two doubler units). When line

 

 

 

powering of more than two devices is required, the line unit automatically

 

 

 

switches to ±123 Vdc.

 

 

 

 

Remote Provisioning

RTPV

ENA

Enables remote provisioning.

 

 

DIS

Disables remote provisioning.

 

 

 

 

Bipolar Violation

BPVT

ENA

Enables BPVs and HDSL4 CRC errors at the DS1 input to be converted into

Transparency

 

 

DS1 BPVs at the DS1 output at the distant end. This makes HDSL4

See “Bipolar

 

 

transparent to BPVs.

Violation

 

DIS

Disables BPV Transparency.

Transparency

 

 

 

(BPVT) Option” on

 

 

 

page 22.

 

 

 

DS1 BER Threshold DBER

See “DS1 Bit Error

Rate (DBER) Option” on page 22.

ENA

Enables the fixed 24-hour DS1 BER threshold.

DIS

Prevents the generation of a system alarm due to DS1 BER.

Continued

20

September 12, 2003

H4TU-C-319 List 1

Page 28
Image 28
ADC HDSL4 H4TU-C-319 List 1 ADC Config Menu Options, Dis, Def, ADC Config Menu Screen Selection Description Options, Ena