ADC H4TU-C-319 List 1 Line Unit Resetting to Factory Default, Disabling an Alarm, Loopback Modes

Models: H4TU-C-319 List 1 Line Unit HDSL4

1 79
Download 79 pages 48.61 Kb
Page 19
Image 19

LTPH-UM-1031-03, Issue 3

Provisioning

 

 

Resetting to Factory Default

All user options for the H4TU-C-319 List 1 (Table 5 on page 19) can be set to the factory default values using the MODE and SEL pushbuttons. To set the user options to their default values:

1Press the SEL pushbutton for 6 seconds until the following message appears:

DFLT NO

2Press the SEL pushbutton while the DFLT NO message is displayed.

The message changes to DFLT YES indicating the factory default values are now in effect and the display returns to the normal mode.

To terminate the DFLT mode without setting the factory default values, do one of the following:

Press the MODE pushbutton to return to the normal display mode.

Wait 30 seconds for the unit to return to the normal display mode.

Displaying System Parameter Settings

To scroll through the current settings of all system parameters, press the MODE pushbutton for 3 or more seconds. The H4TU-C-319 displays the following parameters:

Software version number

List number

Type of frame pattern received from the DSX-1

Line code of the signal received from the DSX-1

All user-configured parameter settings

Loop attenuation threshold setting

Margin alarm threshold setting

Disabling an Alarm

System alarms can be disabled by pressing the SEL pushbutton on the H4TU-C-319 front panel for less than 3 seconds. This executes an ACO and returns the H4TU-C-319 to its non-alarm state. For more information about alarms, see “System Alarms” on page 42.

Loopback Modes

See “Loopback Operation” on page 46 for instructions on using the MODE and SEL pushbuttons to activate loopbacks.

H4TU-C-319 List 1