Provisioning

LTPH-UM-1031-03, Issue 3

 

 

Clearing the History, Alarm, and Event Log Screens

Select Master Clear to clear the History, Alarm, and Event Log screens after the system has been installed and is functioning properly. This removes miscellaneous data acquired during the startup session and ensures collection of accurate and meaningful data thereafter.

Monitor

Performance Event Log

Config

Inventory

Report Rlogon

Help

 

----------------------+

 

 

+

 

 

Standard Options ->

 

 

ADC Options

->

 

 

 

BERT Generator

->

 

Date and Time

->

 

 

Master Clear

 

 

 

 

Set Factory Defaults

 

+----------------------

 

 

+

 

Clear ALL performance, alarm and event log entries. Are you sure (Y/N)?

ID: xxxx--xxxx—-xxxx--xxxx 02/01/2002 12:30:01 H4TU-C System: OK___

Figure 10. Config Menu - Master Clear

To clear the Event Log, press E to select the Event Log screen, then press L to clear the screen.

To clear an individual history or alarm screen, do the following:

1Press P to select the Performance screen.

2Press the SPACEBAR to select either interface (H4TU-C DS1, H4TU-R DS1, H4TU-C HDSL, H4DU-1 NET HDSL, H4DU-1 CPE HDSL, H4DU-2 NET HDSL, H4DU-2 CPE HDSL, or H4TU-R HDSL), then press ENTER .

3Press to select statistics.

4Press the SPACEBAR to select the type of statistics (Current, Alarm History, 25-Hour History, 48-Hour History, or 31-Day History), and press ENTER after your selection.

Selecting 31-Day History allows you to clear the current, 25-hour, 48-hour, and 31-day performance history screens for the selected interface.

Selecting Alarm History allows you to clear the alarm history screen for the selected interface. For information about the DS1 and HDSL4 Alarm screens, see Table 11 on page 36.

5Press L to clear the screen.

6Press Y to confirm.

To clear ALL history, alarm, and event log screens by this method:

1Press C to select the Config screen.

2Use the and arrow keys to select Master Clear.

3Press ENTER to activate.

4Press Y to confirm (clear all screens).

24