176 6000 Series Oscilloscope User’s Guide
4 Triggering the Oscilloscope
As you set stage, term, and channel definitions for the sequence
trigger, these settings will be shown in the waveform area of the
display.
Channel
select
Stage
select
Find, Trigger on,
or Reset condition
Define
term
Trigger level
or threshold
Sequence
trigger
Return to
previous menu
Select
term
Selected
channel
Sequence stage
definitions
Term definitions