Index

Symbols

(-)Width measurement, 246 (+)Width measurement, 246

Numerics

1*2 math function, 215

1-2 math function, 217

232, 109

6000L, 8, 21

A

about oscilloscope, 108 AC adapter, 36

AC channel coupling, 85 accessories, 22, 26, 27 acquire, 268 acquisition memory, 130 acquisition mode, 265

averaging, 267, 268 high resolution, 266 normal, 266

peak detect, 266 acquisition option

realtime, 269 active probes, 56

active serial bus, 275, 279, 284, 293 activity indicator, 118

adding digital channels license, 334 addition, 217

address with no ack condition, I2C trigger, 166

Addresses softkey, 39 adjust the handle, 28 aliasing, FFT, 223 ALT, 109

Amplitude measurement, 251 AMS, 109

AMS license, 109 analog channel

probe attenuation, 87 setup, 83

analog filters, adjusting, 223 analog probes, 51

ASCII file format, 325 attenuation factor, 81 attenuation, probe, 87, 136 Auto Increment, 323

Auto trigger indicator, 71, 131 auto trigger mode, 80, 131 Auto? trigger indicator, 131 automatic measurements, 96, 239 automatic setup, 80, 116 AutoProbe, 64, 70, 85

external trigger, 137 AutoScale, 80

acquisition mode, 313 channels, 313 digital channels, 116 undo, 312

autoscale key, 73 auto-single, 79

Average measurement, 251 averaging acquire mode, 267, 268

B

bandwidth limit, 86 bandwidth, oscilloscope, 270 Base measurement, 251 BAT option, 34

battery life, 34

battery power indicator, 34

battery, charging, 36 battery, replacing the, 36 BIN file format, 325 binary cursors, 233 binary data (.bin), 346 binary data file examples, 351 binary data in MATLAB, 346 binary data, example program for

reading, 350 bits, SPI trigger, 187 blanking, 94, 211 BMP file format, 324 brightness of waveforms, 63, 69 Browser Web Control, 45

bus display mode, 122

C

calibrate probe, 88 CAN decode

source channels, 283 CAN frame counter, 286 CAN serial decode, 281 CAN Signals Menu, 282 CAN totalizer, 286 CAN trigger, 148 caution indicator, 34 Center, FFT, 226

6000 Series Oscilloscopes User’s Guide

363

Page 363
Image 363
Agilent Technologies 6000 Series manual Index

6000 Series specifications

Agilent Technologies has long been recognized as a leader in the field of electronic measurement and test equipment, and the Agilent 6000 Series oscilloscopes exemplify this commitment to innovation and quality. Designed for both professional engineers and researchers, the 6000 Series offers a comprehensive suite of features that enhance usability, accuracy, and efficiency in various applications.

At the heart of the Agilent 6000 Series is its advanced architecture, which integrates a high-performance analog-to-digital converter (ADC) and a sophisticated digital signal processing engine. This combination enables users to capture fast, high-resolution signals with remarkable accuracy, making it suitable for a wide range of applications, from automotive to telecommunications.

One of the standout features of the 6000 Series is its bandwidth options, which typically range from 100 MHz to 500 MHz. This flexibility allows users to select an oscilloscope that best fits their specific needs. Coupled with a sampling rate of up to 4 GSa/s, the 6000 Series offers exceptional timing resolution, ensuring that even the most fleeting signals are accurately represented.

The user interface of the 6000 Series is designed for maximum efficiency. The oscilloscopes are equipped with a large, high-resolution display, enabling users to view complex waveforms in detail. Furthermore, the touch screen interface provides a level of interactivity that simplifies navigation through various functions, making it accessible for both seasoned professionals and novices alike.

Additionally, the 6000 Series incorporates advanced triggering capabilities, allowing users to isolate specific events in their signals easily. The wide array of available triggering options includes edge, pulse width, and serial triggering formats, which are vital for analyzing complex digital communications.

Another noteworthy characteristic of the Agilent 6000 Series is its built-in measurement and analysis tools. The oscilloscopes come equipped with automated measurements, enabling users to quickly gather important data about their signals without manual calculations. This reduces the time spent on testing and increases overall productivity.

In terms of connectivity, the 6000 Series includes USB and LAN interfaces, providing easy data transfer and integration with other devices. The inclusion of advanced software options further enhances data analysis capabilities, enabling users to perform extensive post-acquisition analysis.

In summary, Agilent Technologies' 6000 Series oscilloscopes represent a blend of cutting-edge features, user-friendly design, and high-performance technologies, making them an invaluable tool for engineers and scientists engaged in electronic measurements and analysis. Their versatility and power make them well-suited to meet the demands of modern engineering challenges.