Remote operation

 

HSCSD Subsystem GPIB Commands

 

HSCSd:MASTer:UPLink:AMPLitude

Description

This sets the expected input level of the master TCH. In standard mode,

 

this sets the master’s uplink amplitude control to MANUAL. In

 

compatibility mode, if the master’s uplink amplitude control is set to MS

 

TX LEV then an error message Can’t change setting while MS TX

 

Lev mode is selected. occurs and the setting is not performed.

 

If the measurement timeslot is set to Master, the analyser level of the

 

unit is set to this value.

Syntax

HSCSd:MASTer:UPLink:AMPLitude?

 

HSCSd:MASTer:UPLink:AMPLitude <real> <units>

Command options

Type

float

 

 

Units:

dBm only

 

 

Limits (GSM900):

-27.0 thru +41.0

 

 

Limits (E-GSM):

-27.0 thru +41.0

 

 

Limits (DCS1800):

-47.0 thru +33.0

 

 

Limits (PCS1900):

-47.0 thru +33.0

 

 

Default (compatibility mode):

33.0

 

 

Default (GSM900)

13.0

 

 

Default (E-GSM):

13.0

 

 

Default (DCS1800):

10.0

 

 

Default (PCS1900):

10.0

 

 

52

Chapter 5

Page 66
Image 66