Remote operation

 

HSCSD Subsystem GPIB Commands

 

HSCSd:MASTer:UPLink:AMPLitude:CONTrol

Description

This defines the relationship between the master’s Tx level, and the

 

master’s expected uplink amplitude. MS TX LEV indicates that setting

 

the master’s Tx level also sets the master’s expected uplink amplitude.

 

MANUAL indicates that setting the master’s expected uplink amplitude is

 

independent from the value of the master’s Tx level.

 

Note that in standard mode, setting either the master’s Tx level, or the

 

master’s expected uplink amplitude, forces the value of the master’s

 

amplitude control to MS TX LEV or MANUAL respectively.

Syntax

HSCSd:MASTer:UPLink:AMPLitude:CONTrol?

 

HSCSd:MASTer:UPLink:AMPLitude:CONTrol <string>

Command options

‘MS TX LEV’ ‘MANUAL’