Agilent Technologies 8922 P manual Pause

Models: 8922 P

1 94
Download 94 pages 14 Kb
Page 81
Image 81

Remote operation

Example code showing a dual-band handover from E-GSM to DCS

350! enabled, it will IMMEDIATELY return ENABLED

360!

370! Select the HSCSD screen - it's easier to see what's

380! happening for now

390OUTPUT Master;"DISP HSCSD"

400OUTPUT Slave;"DISP HSCSD"

410!

420! Dial in RF losses

430!

440OUTPUT Master;"Conf:OFLevel:RFInOut ";-1*Master_loss

450OUTPUT Master;"Conf:OFLevel:Mode 'On'"

460OUTPUT Slave;"Conf:OFLevel:RFInOut ";-1*Slave_loss

470OUTPUT Slave;"Conf:OFLevel:Mode 'On'"

480!

490! select big tx levels

500OUTPUT Master;"HSCSD:Master:TCH:TLevel 5"

510OUTPUT Slave;"HSCSD:Slave:TCH:TLevel 5"

520!

530! Get a call up

540!

550! Make sure master is listening to master uplink

560!

570OUTPUT Master;"HSCSD:Measure:TSlot 'Master'"

580!

590! and wait for the call

600!

610PRINT "Make a call from the mobile..."

620REPEAT

630

WAIT .5

640OUTPUT Master;"Cell:Call:Stat:Stat?"

650ENTER Master;Stat$

660UNTIL Stat$="""CONNECTED"""

670PRINT "Call connected, press CONTINUE key to continue..."

680PAUSE

690!

700! Now perform a dual band handover 710 !

720OUTPUT Master;"Disp DBand"

730OUTPUT Slave;"Disp DBand"

740OUTPUT Master;"DualBand:TCH:DCS 615"

750OUTPUT Master;"DualBand:TLevel:DCS 6"

760OUTPUT Master;"DualBand:Atten:GBCH '10 dB'"

770OUTPUT Master;"DualBand:Amplitude:DTCH -55 dBm"

780OUTPUT Slave;"DualBand:TCH:DCS 615"

790 OUTPUT Slave;"DualBand:TLevel:DCS 6

800OUTPUT Slave;"DualBand:Atten:GBCH '10 dB'"

810OUTPUT Slave;"DualBand:Amplitude:DTCH -55 dBm"

Chapter 5

67

Page 81
Image 81
Agilent Technologies 8922 P manual Pause