Agilent Technologies 8922 P manual HSCSdMASTerTCHARFCn

Models: 8922 P

1 94
Download 94 pages 14 Kb
Page 62
Image 62

 

Remote operation

 

HSCSD Subsystem GPIB Commands

 

HSCSd:MASTer:TCH:ARFCn

Description

Setting this during a call forces a channel assignment to the given

 

channel. Note that existing channel assignment commands sent to a

 

master or single unit have the same effect. In particular, a dual band

 

assignment must be performed using the existing dual band commands.

 

If the measurement timeslot is not set to “Master”, attempting to

 

perform a channel assignment on a master or single unit will produce an

 

error, and the setting will be ignored. The error message is Select

 

Master to measure before signalling mobile. When the system is

 

idle (that is, not on a call) this sets the channel which will be used when

 

the next call is established. This command must also be sent to the slave

 

unit.

Syntax

HSCSd:MASTer:TCH:ARFCn <integer>

 

HSCSd:MASTer:TCH:ARFCn?

Command options

Type

integer

 

 

Units:

none (ARFCN)

 

 

Limits (GSM900):

1 thru 124

 

 

Limits (E-GSM):

0 thru 124; 995 thru 1024

 

 

Limits (DCS1800):

512 thru 885

 

 

Limits (PCS1900):

512 thru 810

 

 

Default (GSM900):

30

 

 

Default (E-GSM):

30

 

 

Default (DCS1800):

512

 

 

Default (PCS1900):

51

 

 

48

Chapter 5

Page 62
Image 62
Agilent Technologies 8922 P manual HSCSdMASTerTCHARFCn