Quick Reference 1

SCPI Command Summary

Subsystem Commands

 

 

Some [optional] commands have been included for clarity. All settings commands

 

NOTE

 

have a corresponding query. Not all commands apply to all models.

 

 

 

 

 

 

 

 

 

SCPI Command

 

Description

ABORt

 

 

:ACQuire (@chanlist)

 

Resets the measurement trigger system to the Idle state

:TRANsient (@chanlist)

 

Resets the transient trigger system to the Idle state

CALibrate

 

 

:CURRent

 

 

[:LEVel] <NRf>, (@channel)

 

Calibrates the output current programming

:MEASure <NRf>, (@channel)

 

Calibrates the current measurement

:PEAK (@channel)

 

Calibrates the peak current limit (Agilent N6751A/52A/61A/62A)

:DATA <NRf>

 

Enters the calibration value

:DATE <SPD>, (@channel)

 

Sets the calibration date

:DPRog (@channel)

 

Calibrates the current downprogrammer

:LEVel P1 P2 P3

 

Advances to the next calibration step

:PASSword <NRf>

 

Sets the numeric calibration password

:SAVE

 

Saves the new cal constants in non-volatile memory

:STATE <Bool> [,<NRf>]

 

Enables/disables calibration mode

:VOLTage

 

 

[:LEVel] <NRf>, (@channel)

 

Calibrates the output voltage programming

:CMRR (@channel)

 

Calibrates common mode rejection ratio (N6751A/52A/61A/62A)

:MEASure <NRf>, (@channel)

 

Calibrates the voltage measurement

DISPlay[:WINDow]:VIEW METER1 METER4

Selects 1-channel or 4-channel meter view

FETCh

 

 

[:SCALar]

 

 

:CURRent [:DC]? (@chanlist)

 

Returns the average output current

:VOLTage [:DC]? (@chanlist)

 

Returns the average output voltage

:ARRay

 

(Array commands only on Agilent N6761A/62A and Option 054)

:CURRent [:DC]? (@chanlist)

 

Returns the instantaneous output current

:VOLTage [:DC]? (@chanlist)

 

Returns the instantaneous output voltage

INITiate

 

 

[:IMMediate]

 

(Acquire command only on Agilent N6761A/62A and Option 054)

:ACQuire (@chanlist)

 

Enables the measurement system to receive triggers

:TRANsient (@chanlist)

 

Enables the output transient system to receive triggers

:CONTinuous

 

 

:TRANsient <Bool>, (@chanlist)

 

Enables/disables continuous transient triggers

MEASure

 

 

[:SCALar]

 

 

:CURRent [:DC]? (@chanlist)

 

Takes a measurement; returns the average output current

:VOLTage [:DC]? (@chanlist)

 

Takes a measurement; returns the average output voltage

:ARRay

 

(Array commands only on Agilent N6761A/62A and Option 054)

:CURRent [:DC]? (@chanlist)

 

Takes a measurement; returns the instantaneous output current

:VOLTage [:DC]? (@chanlist)

 

Takes a measurement; returns the instantaneous output voltage

Series N6700 User’s Guide

15

Page 15
Image 15
Agilent Technologies N6700 manual Scpi Command Summary, Subsystem Commands, Scpi Command Description