Quick Reference 1

Output On/Off sequencing A turn-on/turn-off delay capability for each output allows output on/off sequencing.

Remote voltage sensing

Two remote sensing terminals are provided for each output. When shipped,

 

the remote sense jumpers are included in a separate bag. See Chapter 2.

Voltage and current

All power modules can measure their own output voltage and current.

measurements

 

Voltage, current, and

Each output has over-voltage, over-current, and over-temperature

temperature protection

protection. Over-voltage and over-current protection are programmable.

 

When activated, the protection circuits cause the voltage to go to zero, the

 

output to be disabled, and the protection status to be reported.

System Features

SCPI language

The instrument is compatible with the Standard Commands for

 

Programmable Instruments (SCPI).

Choice of three interfaces GPIB (IEEE-488), LAN, and USB remote programming interfaces are built in.

Front panel I/O setup Menus let you set up GPIB and LAN parameters from the front panel. Refer to Chapter 3 for details.

Built-in Web server

A built-in Web server lets you control the instrument directly from an

 

internet browser on your computer. Refer to Chapter 3 for details.

Real-time status

The front panel indicates the status of each output. It also indicates when

information

a protection shut-down has occurred.

Module identification

Each module has identifying data stored in non-volatile memory.

 

Information includes model number, serial number, and options. This

 

information can be displayed on the front panel.

Model Differences

Feature

 

DC Power Modules

Autoranging Modules

Precision Modules

 

N6731B - N6741B - N6773A -

N6751A

N6752A

N6753A

N6761A

N6762A

 

N6736B

N6746B

N6776A

 

 

N6754A

 

 

Output power rating

50 W

100 W

300 W

50 W

100 W

300 W

50 W

100 W

Autoranging output capability

NO

NO

NO

YES

YES

YES

YES

YES

Precision output and measurement capability

NO

NO

NO

NO

NO

NO

YES

YES

Low voltage output and measurement range

NO

NO

NO

NO

NO

NO

YES

YES

Low current output and measurement range

NO

NO

NO

NO

NO

NO

YES

YES

Simultaneous voltage and current measurement

NO

NO

NO

NO

NO

NO

YES

YES

100 microampere measurement range

NO

NO

NO

NO

NO

NO

Option

Option

Output list capability (Test Extensions)

NO

NO

NO

Option

Option

Option

YES

YES

Array readback capability (Test Extensions)

NO

NO

NO

Option

Option

Option

YES

YES

Programmable sample rate (Test Extensions)

NO

NO

NO

Option

Option

Option

YES

YES

Double-wide

NO

NO

NO

NO

NO

YES

NO

NO

 

 

 

 

 

 

 

 

 

Series N6700 User’s Guide