Cabinet Hardmount
A Control and V Control
H – Control Voltage High (greater than 10V DC) |
|
|
|
|
|
|
|
| 0 = No signal received |
|
| |||||
L – Control Voltage Low (less than 1V DC) |
|
|
|
|
|
|
|
|
| 1 = Signal received |
|
| ||||
|
| SW2 | SW1 | SW3 | Rev | Stop | Fwd |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
DC Volt Meter Red Probe Terminal Location | 27 | 28 | 26 | 22 | 20 | 19 |
| Input Status – Parameter 55 |
| |||||||
DC Volt Meter Black Probe Terminal Location | 29 | 29 | 29 | 29 | 29 | 29 |
|
|
|
|
|
|
|
|
| |
| Frequency | Terminal | Terminal | Terminal | Terminal | Terminal | Terminal | SW2 | SW1 |
| SW3 | Auxiliary | Rev (STR) | Not Used | Stop | Fwd (STF) |
Action | Preset | #27 | #28 | #26 | #22 | #20 | #19 |
| ||||||||
| Parameter # | (SW2) | (SW1) | (SW3) | (STR) | (Stop) | (STF) |
| ||||||||
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Idle | N/A | H | H | H | H | L/H | H | 0 | 0 |
| 0 | 1 | 0 | 0 | 0/1 | 0 |
1/2 Wash Speed Forward | 73 | H | H | L | H | L | L | 0 | 0 |
| 1 | 1 | 0 | 0 | 1 | 1 |
1/2 Wash Speed Reverse | 73 | H | H | L | L | L | H | 0 | 0 |
| 1 | 1 | 1 | 0 | 1 | 0 |
Wash Speed Forward | 28 | L | H | H | H | L | L | 1 | 0 |
| 0 | 1 | 0 | 0 | 1 | 1 |
Wash Speed Reverse | 28 | L | H | H | L | L | H | 1 | 0 |
| 0 | 1 | 1 | 0 | 1 | 0 |
Distribution Speed | 27 | H | L | H | H | L | L | 0 | 1 |
| 0 | 1 | 0 | 0 | 1 | 1 |
Spin 1 | 75 | L | H | L | H | L | L | 1 | 0 |
| 1 | 1 | 0 | 0 | 1 | 1 |
Spin 2 | 29 | L | L | H | H | L | L | 1 | 1 |
| 0 | 1 | 0 | 0 | 1 | 1 |
Spin 3 | 74 | H | L | L | H | L | L | 0 | 1 |
| 1 | 1 | 0 | 0 | 1 | 1 |
Table 54
94 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232120 |