Allen-Bradley 1336-Series AC Drives

Allen-Bradley 1336-Series

1336-Series Drive Control Logic Chart

Pocket Hardmount

WE-6 Control - Design 5 and Earlier

H – Signal Voltage High (approximately 5V DC)

 

 

 

 

 

 

 

 

0 = No Signal Received

 

 

L – Signal Voltage Low (less than 1V DC)

 

 

 

 

 

 

 

 

1 = Signal Received

 

 

 

 

SW2

SW1

SW3

Rev

Stop

Fwd

 

 

 

 

 

 

 

 

 

 

 

 

Input Status –

 

 

DC Volt Meter Red Probe Terminal Location

27

28

26

22

20

19

 

 

 

 

 

 

Parameter #55

 

 

DC Volt Meter Black Probe Terminal Location

29

29

29

29

29

29

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

Terminal

Terminal

Terminal

Terminal

Terminal

Terminal

SW2

SW1

SW3

Auxiliary

(STR)Rev

UsedNot

Stop

(STF)Fwd

 

 

 

 

 

 

 

 

 

Action

Preset

#27

#28

#26

#22

#20

#19

 

 

 

 

 

 

 

 

 

Parameter #

(SW2)

(SW1)

(SW3)

(STR)

(Stop)

(STF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Idle

N/A

H

H

H

H

L/H

H

0

0

0

1

0

0

0/1

0

1/2 Wash Speed Forward

73

H

H

L

H

L

L

0

0

1

1

0

0

1

1

1/2 Wash Speed Reverse

73

H

H

L

L

L

H

0

0

1

1

1

0

1

0

Wash Speed Forward

28

L

H

H

H

L

L

1

0

0

1

0

0

1

1

Wash Speed Reverse

28

L

H

H

L

L

H

1

0

0

1

1

0

1

0

Distribution Speed

27

H

L

H

H

L

L

0

1

0

1

0

0

1

1

Medium Extract/Spray Rinse

75

L

H

L

H

L

L

1

0

1

1

0

0

1

1

High 1 Extract

74

H

L

L

H

L

L

0

1

1

1

0

0

1

1

High 2 Extract

29

L

L

H

H

L

L

1

1

0

1

0

0

1

1

High 3 Extract

76

L

L

L

H

L

L

1

1

1

1

0

0

1

1

Pocket Hardmount

WE-6 Control Designs 6, 7 and 8

H – Signal Voltage High (approximately 5V DC)

 

 

 

 

 

 

 

 

0 = No Signal Received

 

 

L – Signal Voltage Low (less than 1V DC)

 

 

 

 

 

 

 

 

1 = Signal Received

 

 

 

 

SW2

SW1

SW3

Rev

Stop

Fwd

 

 

 

 

 

 

 

 

 

 

 

 

Input Status –

 

 

DC Volt Meter Red Probe Terminal Location

27

28

26

22

20

19

 

 

 

 

 

 

Parameter #55

 

 

DC Volt Meter Black Probe Terminal Location

29

29

29

29

29

29

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

Terminal

Terminal

Terminal

Terminal

Terminal

Terminal

SW2

SW1

SW3

Auxiliary

(STR)Rev

UsedNot

Stop

(STF)Fwd

Action

Preset

#27

#28

#26

#22

#20

#19

 

 

 

 

 

 

 

 

 

Parameter #

(SW2)

(SW1)

(SW3)

(STR)

(Stop)

(STF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Idle

N/A

H

H

H

H

L/H

H

0

0

0

1

0

0

0/1

0

1/2 Wash Speed Forward

73

H

H

H

H

L

L

0

0

0

1

0

0

1

1

1/2 Wash Speed Reverse

73

H

H

H

L

L

H

0

0

0

1

1

0

1

0

Wash Speed Forward

28

L

H

H

H

L

L

1

0

0

1

0

0

1

1

Wash Speed Reverse

28

L

H

H

L

L

H

1

0

0

1

1

0

1

0

Distribution Speed

27

H

L

H

H

L

L

0

1

0

1

0

0

1

1

Medium Extract/Spray Rinse

75

L

H

L

H

L

L

1

0

1

1

0

0

1

1

High Extract Speed 1

74

H

L

L

H

L

L

0

1

1

1

0

0

1

1

High Extract Speed 2

29

H

L

L

L

L

H

0

0

1

1

0

0

1

1

High Extract Speed 3

76

H

H

L

H

L

L

1

1

1

1

0

0

1

1

(Default)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Extract Speed 3

76

H

H

L

H

L

L

0

0

1

1

0

0

1

1

(Maximum)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 52

92

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232120