Control Terminal Block Designations

Terminal

Signal

Machine Use

Number

 

 

TE

True Earth

Not Used

 

 

 

 

1, 2, 3

External Speed Pot

Select Machines

 

Only

 

 

 

 

 

 

 

4

 

Signal Common

Specialty

 

 

Machines Only

 

 

 

 

 

 

 

5

 

0 – 10V DC Input

Specialty

 

 

Machines Only

 

 

 

 

 

 

 

6

 

4 – 20 mA Input

Specialty

 

 

Machines Only

 

 

 

 

 

 

 

7,

8

Pulse Input for

Specialty

Frequency

Machines Only

 

 

 

 

 

 

9

 

Analog Output

Not Used

 

 

 

10, 11

Programmable Contact

Not Used

 

 

 

11, 12

Run Contact

Not Used

 

 

 

 

 

 

Fault Contact NO

Fault Indicator

13,

14

 

Light (Some

 

 

 

Machines)

14,

15

Fault Contact NC

Not Used

 

 

 

 

16,

17

Alarm Contact NO

Balance Relay

 

 

 

 

17,

18

Alarm Contact NC

Not Used

 

 

 

A1, A2

Future Use

Not Used

 

 

 

 

19,

29

STF

Forward Motion

 

 

 

 

 

 

Stop

Drive Balance

20,

21

 

Switch Interlock

 

 

 

Relay or Jumper

21

Common

 

 

 

 

 

22,

29

STR

Reverse Motion

 

 

 

 

23,

21

Input

Not Used

 

 

 

 

 

 

Input

Motor Thermal

24,

25

 

Switch (Some

 

 

 

Machines)

25

Common

 

28,

29

SW1

Preset Speed Input

 

#1

 

 

 

 

 

 

 

27,

29

SW2

Preset Speed Input

 

#2

 

 

 

 

 

 

 

26,

29

SW3

Preset Speed Input

 

#3

 

 

 

 

 

 

29

Common

 

 

 

 

 

 

 

Enable

Balance Switch,

30,

29

 

Drive Interlock or

 

 

 

Jumper

 

 

Table 50

 

Allen-Bradley 1336-Series AC Drives

Torque Specifications

Max/Min Wire Size

 

Maximum Torque

mm2 (AWG)

 

N-m (lb-in)

2.1/0.3

 

1.36

(14/22)

 

(12)

Table 51

 

F232120

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

91