MVP-WDS Wall Docking Station & CB-MVPWDS Conduit Box
18 MVP-WDS Wall Docking Station for MVP Panels
Installing the MVP-WDS-SK Silver Conversion Kit
The VP-WDS-SK Silver Conversion Kit (FG5965-22) contains the following components:
One Silver Cradle Bezel/Faceplate (60-5965-20SL)
One Silver Cradle Pivot (Support Cradle) (60-5965-21SL)
One Silver Battery Cover (60-5965-22SL)
One securing rare earth magnet (63-5965-02)
One securing magnet cup (63-5965-03)
One #4-20 Magnet Securing screw (80-0193-01)
Two plastic Die Cut Foam covers (60-5965-47)
Installation of the kit involves four different sets of procedures:
Removing the original faceplate.
Removing the original pivot unit (consisting of the battery cover and support cradle).
Installing the new conversion kit’s pivot unit components.
Installing the new silver faceplate.
The Conversion Kit cannot be installed while the WDS in a wall or conduit box. If the WDS is mounted,
remove ot before continuing.

Removing the original faceplate

1. Remove the previously installed MVP-WDS from its current location by following the procedures
outlined within the Installationsection on pa ge 4.
2. Carefully remove the previously adhered Die Cut Foam covers from the WDS backplate (FIG.18).
These must be removed to gain access to the two #6-32 Faceplate Security Screws. New covers are
included with the MVP-WDS-SK Conversion Kit.
3. Place the back of the MVP-WDS Docking Station on a flat level surface.
4. Connect the 3.5 mm mini-Phoenix connector from an active power supply to the side PWR
connector on the MVP-WDS. This action provides power to the docking station and allows you to
open the MVP Support Cradle. The two blue LEDs behind the Security Release pushbutton should
illuminate to indicate that the unit is receiving power.
5. Open the Battery Compartment by pressing down on the Battery Compartment Latch and pulling
the cover outwards.
6. Press the Cradle Activation pushbutton (FIG.18) to make the MVP Support Cradle rise upwards.
The MVP Support Cradle must be angled upward to allow removal of the faceplate.
When installing the MVP-WDS-SK it is recommended that you use a long magnetic
Phillips-head screwdriver. The magnetic screwdriver prevents removed screws from
falling into the unit and possibly damaging components.
Static electricity can damage electronic circuitry. Before touching the unit, discharge
any accumulated static electricity from your body by touching a grounded metal
object.