Index

D

Data verification, required browser settings, 20

Date/Time option, System menu, 32

Default settings, restoring, 32 Delete Log button, 51 Description column, in event

list, 59

Detailed Status option, UPS menu, 35

Detailed UPS Information option

Device Manager menus, 36 UPS menu, 35

Device Manager menu options

Detailed UPS Information, 36 diagnostic test options, 40 Input Voltage, 36

Output Voltage, 37 PowerChute, 34 UPS, 34

UPS Control options, 42

Device Manager option, Control Console menu, 19

Devices that support the Management Card, 8 Diagnostic test options

Self-Test,40

Simulate Power Failure, 40

Start/Stop Runtime

Calibration, 40

Test UPS Alarm, 40

Disabled access by an NMS, 29 Disabling

BOOTP, 27

email for an event, 60 email to a recipient, 57 event logging, 54

sending any traps to an NMS, 55 sending authentication traps to an

NMS, 55

traps for an event, 60 turn-off options on Silcon

DP300E, 41

use of a proxy server, 20

DNS

defining DNS address, 27 option on Network menu, 27, 56

Domain Name Server (DNS), 27 Downloading configuration files

with FTP, 28 with TFTP, 28

E

Electrical specifications, 78 Email

configuring, 56, 58 disabling for an event, 60 Email Test option, 57 enabled by default for severe

events, 54

enabling and disabling, 57 enabling for an event, 60 option on Events menu, 54, 57 reason to use local DNS

server, 56

setting up an account for the Management Card, 58

using for paging, 57

Email Recipients settings

Email Generation, 57

Send via, 57

To Address, 57

Enabling

BOOTP, 27

email for an event, 60 email forwarding to external

SMTP servers, 58 email to a recipient, 57 sending any traps to an NMS, 55 sending authentication traps to an

NMS, 55

traps for an event, 60 turn-off options on Silcon

DP300E, 41

Encryption not supported, 68 Environment menu options

About Environmental Monitor, 49

Status, 49

Threshold and Contact

Details, 49

Environmental Monitoring SmartSlot Card

Contact Settings, 49 Contact Status fields, 49 events listed and described, 66 High or Low Humidity Violation

field, 49

High or Low Temperature Violation field, 49

Humidity field, 49 Probe Settings, 49 status

in Web interface, 22 on Control Console main

screen, 18 Temperature field, 49

Error messages, 21

Event log

accessing, 14 deleting the log

by typing d, 51 Delete button, 51 delete command, 52

disabling logging, 54 displaying the log

Ctrl-L,51

Log option, 51

Event Log option, Events menu, 54

Event mask codes for event configuration, 60

Event Notification Port parameter, 48

event.txt file

contents, 52

importing into spreadsheet, 52

Events listed and described

Environmental Monitoring Card events, 66

Management Card events, 61 System events, 61

UPS events, 62

Events menu options

Actions, 53

Email (Web Interface), 54 Event Log, 54

Log, 51

Recipients (Web interface), 57 SNMP traps, 54

evntlist.htm

format and column contents, 59 purpose, 59

External Batteries parameter, 46

Web/SNMP Management SmartSlot Card User’s Guide

79

Page 79
Image 79
APC AP9606 manual Index, Device Manager menu options

AP9606 specifications

The APC AP9606 is a sophisticated environmental monitoring device designed to enhance the functionality and efficiency of data centers and critical IT environments. As part of APC’s suite of infrastructure solutions, the AP9606 is primarily aimed at monitoring conditions in rack-mounted and remote locations. By implementing advanced features and technologies, it ensures that environmental conditions remain optimal to prevent equipment failure and provide high availability for business operations.

One of the main features of the AP9606 is its ability to monitor and report various environmental factors including temperature, humidity, and other critical conditions. This real-time monitoring capability allows IT managers to react promptly to changing environmental variables which can significantly impact server and equipment performance. The device can be connected to a multitude of sensors, enabling users to customize their monitoring setups depending on specific requirements.

The AP9606 utilizes SNMP (Simple Network Management Protocol) for seamless integration with existing network management systems. This protocol allows easy communication between the device and other network elements, further enabling IT departments to consolidate and manage their infrastructure efficiently. Additionally, support for web-based interfaces gives users the flexibility to access real-time data from virtually anywhere, facilitating remote management capabilities which are crucial for businesses with multiple locations.

In terms of connectivity, the AP9606 is equipped with multiple ports, including an Ethernet port for network connection and optional serial ports for connecting with compatible devices. The inclusion of both wired and wireless options ensures that the device can adapt to various network environments, making it particularly versatile.

One of the standout characteristics of the APC AP9606 is its scalability. As businesses evolve, so do their monitoring needs. The AP9606 can be easily expanded with additional sensor modules, allowing businesses to grow their monitoring capabilities without needing entirely new systems. This flexibility makes it a cost-effective solution in the long run.

In summary, the APC AP9606 environmental monitoring device stands out due to its comprehensive monitoring features, robust connectivity options, and scalability. It is particularly well-suited for data centers and critical infrastructure environments where maintaining optimal conditions is essential. By investing in the AP9606, businesses can ensure they are proactively managing their IT assets, ultimately leading to improved operational performance and reduced risk of equipment failure.