10

Wiring Diagram

+ 5 VDC
Microphone 1 Signal
Shield
Shield
Microphone 2 Signal
Microphone 3 Signal
Program
Phone
Status
POWER
J5
Mic Inputs
+123
Com
Siren
2-Way
Red
Green
White
Black
Gel Lead Acid
type Batteries
6-Wire Keypad
RK36 current draw 50mA
2-Violet :
Internal Speaker Loop
16.5VAC
40VA
Trans.
(supplied) 4.7K
Note: Auxiliary Outputs
are pull-to-ground on
activation at 100mA per
pin. Total Current can
not exceed 500mA.
R1 T1 TR
Ext
Com
Int
AC AC
SMK-
Com
Aux+
Red
Grn
Wht Blk RC RNC RNO
Aux Relay
Hardwire Inputs
12 3456 78Com Com
OnOff
Gray
Brown
Red
Green
Green
Red
White
Black
-
Ground
To House Phones
From Telephone Company
Red
Green
RJ-31X
1
2
3
45
6
7
8
18
RJ-31X
PLUG
External Speaker,
8 10 Watt Min.
+
-
Com
Power Switch
12V DC
7Ah
-
+

Warning: To prevent the

risk of shock, disconnect

telephone line at telco jack

before servicing this unit

Inputs may be wired with no End-of-line resistor, 1 4.7K end-of-line resistor ,
or 2-resistor supervision. See "Wiring an Input" for input diagrams and
"Programming System Inputs to Zones" for programming information.
See
"Specifications" for
compatible smoke
detectors
(See "Specifications"
for compatible speaker)
Internal Speaker,
8 10 Watt Min.
For UL Installations:
Average current draw from the
battery not to exceed 400 mA
Com
4.7K
12V DC
7Ah
-
-
++
2-Wire Smoke
Detector
4-Wire Smoke
Detector
When using smoke reset, program
the Smoke Power Trigger to output
8 (aux relay) 0143,008.
Receiver + bridge 115 mA
Volume
Adjust
U/D
J2