30
User Code 1 2 3 4 5 6 7 8
Location 0065 0066 0067 0068 0069 0070 0071 0072

System Times And Other Options

System Time Options - A description of each time is available in the Glossary Units Location Default
Entry delay 1 (Not to exceed 45 seconds in a UL installation) .............................seconds ....0080 ...... 020 _______
Entry delay 2 (Not to exceed 45 seconds in a UL installation) .............................seconds ....0081 ...... 020 _______
Exit delay (Not to exceed 60 seconds in a UL installation) ..................................seconds ....0082 ...... 030 _______
Alarm cut off and reset (Not to be less than 4 minutes in a UL installation).........minutes.....0083 ...... 005 _______
* Duration between fire, tamper, trouble chirps ..................................................seconds ....0086 ...... 005 _______
* Duration for recognition of AC power loss .......................................................minutes.....0097 ...... 001 _______
Duration between spoken "Pre-alarm" cycles (000 = 3 seconds) .........................seconds ....0099 ...... 000 _______
Fire siren tone duration before speech ................................................................seconds ....0101 ...... 005 _______
Burglary siren tone duration before speech .........................................................seconds ....0102 ...... 005 _______
Fire cut off and reset (Not permitted in a UL installation) ....................................minutes.....0100 ...... 005 _______
Number of 4 second samples to determine loss of phone line ............................samples ....0456 ...... 006 _______
Time frame for User Test Timeout........................................................................minutes.....0098 ...... 003 _______
Answer service callback override wait time ........................................................seconds ....0470 ...... 025 _______
Number of rings for pickup (minimum of 002, 000 disables ) .............................rings .........0458 ...... 010 _______
Inactivity time before automatic hang up while in user phone access .................seconds ....0556 ...... 015 _______
Inactivity time before automatic hang up/exit when programming......................seconds ....0557 ...... 060 _______
Delay before dialing after activation Phone #1 (000 - disables) ..........................seconds ....0437 ...... 002 _______
Delay before dialing after activation Phone #2 (000 - disables) ..........................seconds ....0438 ...... 002 _______
Off-hook time during listen-in before automatic hang-up (000 - 256 seconds) ....seconds ....0453 ...... 120 _______
Central Station handshake wait period................................................................seconds ....0455 ...... 025 _______
Two-way callback from central station wait period .............................................minutes.....0461 ...... 002 _______
Voice only and two-way callback wait period for a valid code...........................seconds ....0465 ...... 060 _______
Maximum number of dialing attempts Phone #1.................................................attempts ....0449 ...... 008 _______
Maximum number of dialing attempts Phone #2.................................................attempts ....0450 ...... 008 _______
Touch tone (000) or pulse (001) dialing.................................................................................0454 ...... 000 _______
Ignore dial tone (for use with cellular backup) (001 - enabled) .............................................0466 ...... 000 _______
Number of disappearing code activations ...........................................................activation .0073 ...... 001 _______
Number of retries when dialing ..........................................................................attempts ....0185 ...... 008 _______
Activations before Auto-Bypass (Not permitted in a UL installation: 000) ...........activation .0115 ...... 000 _______
Time frame activations occur within (Not permitted in a UL installation) ............hours ........0116 ...... 024 _______
Time extended monitor is displayed on the keypad (000 - continuous) ...............seconds ....0175 ...... 030 _______
Time between speech/beeps when extended monitor is active (000 - disable) ....seconds ....0176 ...... 005 _______
* 000 disables (Must be enabled for UL installation)

User Code Options

Options : Enter total - A description of each option is available in the Glossary Location Value
Duress ........................................................................................................................................... 001
Disappearing ................................................................................................................................. 004
Enable master functions - bypass mode, extended monitor, user code changes ............................. 008
Works on remote telephone ........................................................................................................... 016
Works on keypads.......................................................................................................................... 032
Works on local telephones ............................................................................................................. 064
Generate open report to CS and/or Event Memory log ................................................................... 002
Generate close report to CS and/or Event Memory log ................................................................... 128
Default - User code 1 (all others default 000) .............................................................. 0065 ....... 250
Program Mode Access Code Options............................................................................ 0549 ....... 048