No Exterior Instant

When enabled, this option will eliminate the exit delay on all exterior instant zones

Exit Delay:

following arming to either HOME or AWAY.

No Program Mode:

With this option set, the system will not enter program mode with the panel armed.

Number of Activations

Zones can be automatically bypassed, if the zone causes multiple activations within a

for Auto-Bypass:

specified time frame (reset each time the system is armed). The number of activations

 

and time period are programmable. Once a valid disarm code is entered, the bypassed

 

zone will be unbypassed. A program value of 000 disables this feature. Automatic

 

bypassing of zones is not permitted in a UL installation.

Off-hook Duration:

The system can be programmed to enter two-way after a digital communication. This

 

location determines how long the system will hold the line without a valid two-way

 

command before automatically dropping the line. Valid times are 000 - 255,

 

000 = 256 seconds.

Open zones Bypassed:

With open zones automatically bypassed at "force arm" enabled, zones are not force

 

armed, they are bypassed. Therefore, if a zone is open and the system is force armed,

 

the zone will remain bypassed even if the zone is closed. Without this option set,

 

closing the zone will place the zone back into the system as a monitored input. Bypass

 

is not permitted in a UL installation.

PC Access Code:

Code required for programming the panel via computer software.

Phone Inactivity Hang-up: The amount of time the system will wait without activity before terminating the

 

connection.

Phone Samples:

The built in phone monitor circuit can be adjusted based on the installation location.

 

Every four seconds the phone line is sampled, this option determines the number of

 

samples needed for the panel to determine that a valid phone line has been connected or

 

removed. In locations subject to brief phone outages use a higher number, in locations

 

that have reliable phone service use a lower number. The default 6 works best in most

 

applications.

Program Access Code:

Code required to place the system into program mode.

Program Inactivity:

The amount of inactivity time before the system exits program mode to keypad mode.

Program Code Options:

Works the same as user code options but applies to the program mode access code.

Record in EML:

The system contains a 80 Event Memory Log (EML). Reports that are sent to the central

 

station are available to be sent to the EML. Even if a report is not programmed to be sent

 

to the central station it may still be programmed to be sent to the EML. Each report code

 

can be recorded in the EML by adding the 128 value in the dialer option. The only

 

method for retrieving the EML is with the PC based programming software. Once the

 

EML reaches 80 events, all new events push out the oldest event. The EML can be

 

cleared by entering 9898 from the keypad or phone while in program mode.

Remote Telephone:

Allows use of the code from any off site touch tone phone.

Removing User Codes:

Follow the user code sequence and press the A key when prompted for the user code.

 

NOTE: Code 1 cannot be removed; only changed.

48

Page 48
Image 48
Apex Digital K1106 installation instructions Applications

K1106 specifications

The Apex Digital K1106 is a versatile and compact multimedia player that has gained recognition for its user-friendly interface and impressive range of features. Designed to cater to the needs of modern consumers, the K1106 seamlessly blends function with style, making it an appealing choice for entertainment enthusiasts.

One of the standout features of the Apex Digital K1106 is its support for multiple media formats. Users can enjoy a variety of audio and video files, including popular formats such as MP3, WMA, AVI, and MKV, ensuring compatibility with a wide range of content. This flexibility allows users to play their favorite movies, music, and photos without the hassle of converting files, making it an all-in-one solution for home entertainment.

The K1106 also integrates advanced connectivity options, including HDMI, USB, and composite outputs. The HDMI output delivers high-definition video and audio, creating an immersive viewing experience when connected to HDTVs or projectors. Additionally, the USB port allows users to connect flash drives or external hard drives, making it easy to access a library of multimedia content. The composite output ensures compatibility with older television models, widening its usability across various devices.

Another key characteristic of the Apex Digital K1106 is its user-friendly interface. With an intuitive remote control and on-screen menu, navigating through various options and settings is straightforward, promoting an enjoyable user experience. The compact design of the device is also noteworthy, allowing it to fit seamlessly into any entertainment setup without taking up excessive space.

The device offers various playback features, such as pause, resume, and chapter selection, giving users the flexibility to enjoy their media at their own pace. Moreover, the K1106 supports subtitle files, enhancing the viewing experience for international content or dialogue-heavy films.

In summary, the Apex Digital K1106 is a multifaceted multimedia player that stands out for its broad format compatibility, advanced connectivity options, user-friendly interface, and playback features. Whether for watching movies, listening to music, or viewing photos, this device meets the diverse entertainment needs of its users while maintaining a sleek and compact design. Its combination of technology and practicality makes it a valuable addition to any home entertainment system, appealing to both casual viewers and avid media lovers alike.