26
Zone 28
Input Remote Phone
Option Location Default New Va lue Default Description
Zone Type 1079 255 Word 1 Word 2 Word 3 Word 4
Option 1 1075 000 Remote (1 37) Phone (125) N/A N/A
Option 2 1076 000
Zone 26
Input System Keypad s
Option Location Default New Value
3 – Status 1334 006
6 – Monitor 1335 009
9 – F1 1336 007
1 – 7 1337 255
2 – 8 1338 016
3 – 9 1339 255
Status 1340 005
Monitor 1341 001
F1 1342 000
F2 1343 010
Option 1 1043 080
Word 1 System (1 59)
Word 2 Keypad (092)
Word 3 N/A
Word 4 N/A
Zone 27
Input Local Phone
Option Location Default New Value Default Description
Zone Type 1063 255 Word 1 Word 2 Word 3 Word 4
Option 1 1059 000 House (183) Phone (125) N/A N/A
Option 2 1060 000

Zone 26: System Keypads

All keypad activations report as Zone 26. Keys and
key combinations are fully programmable. Use the
button function list (Zones 24-25) to change the
functionality of the listed keypad inputs. The word
description is predefined as "System Keypad." This
can be changed by altering the zone description for
zone 26. Programming zone descriptions is covered
at the end of this section. Option 1 value 016 (report
to central station) is the only Zone Option that
applies to zone 26.

Zone 27: Local Phone

While in local phone keypad mode, a user can activate a zone by entering 5 zeros. The 5 zero activation is treated
by the system in the same manner as a traditional zone open. Zone Options 1 and 2 apply. This zone is traditionally
programmed as a 24 hour panic. The word description is predefined as "House Phone." This can be changed by
altering the zone description for zone 27. Programming zone descriptions is covered at the end of this section.

Zone 28: Remote Phone / Phone Line Monitor

Loss of phone line is treated by the system in the same manner as a traditional zone open. See System Times And
Other Options (location 0456) to determine the number of 4 second samples before panel detects a loss of phone
line. For notification at the keypad, this input can be programmed as an auxiliary zone type for enunciation at the
keypad, a day zone for extended monitoring and alerts while armed, or a 24 hour panic for alarm activation upon
loss of phone line (not recommended). Zone 28 is reported when an activation occurs from a remote phone (see
User Code + digit). The word description is predefined as "Remote Phone." This can be changed by altering the
zone description for zone 28. Programming zone descriptions is covered at the end of this section.