17

Quick Start

Keypad connection: Connect a hardwire keypad to the keypad terminals on the control board, be certain to
properly match the colors as follows: Black to BLK, Red to RED, Green to GRN, White to
WHT.
Speaker connection: Connect the violet keypad speaker leads to the INT and COM terminals on the control
board.
Power connection: Connect the power transformer to the AC terminals on the control board and plug the
transformer into an unswitched 120 VAC outlet.
Apply power: Turn the power switch to the ON position (right). Wait for a start tone(s) followed by a
pause and two beeps.
Setting time and day: The panel MAY prompt "Press 2 and 8 to set time" if the clock was not set prior to transit
or if the capacitor responsible for sustaining the clock dissipated during transit and
stocking. Press the 2 and 8 keys on the keypad simultaneously. The panel will prompt for
a 4 digit time (use a leading 0 for times under 10:00), followed by a prompt for AM or PM.
The next prompt is for the day of the week (1-Sunday, 2-Monday, 3-Tuesday, 4-
Wednesday, 5-Thursday, 6-Friday, 7-Saturday). Enter a two digit month, two digit date
and two digit year.
Arm and disarm: Press the A key on the keypad and the green AWAY LED will light. ARMED TO AWAY
will be heard through the speaker. To disarm, push 1,2,3,4 (default Primary User Code) on
the keypad. The AWAY LED will go out and "CONTROL IS DISARMED" will be heard.
Default Panel: To ensure erroneous values are not stored in memory from the manufacturing and/or
testing, the panel should be defaulted before installation. Enter 9,1,7,3 followed by
9,9,8,2.
Program: Proceed with programming to suit the installation.