Ademco Contact ID Report Codes

APEX Description Code Sent to Central Station ADEMCO Description
Exterior instant .................................. E131 Z
............................................Perimeter burglary
Exterior delay 1 .................................E134 Z
............................................Entry/exit burglary
Exterior delay 2 .................................E134 Z
............................................Entry/exit burglary
Interior instant ...................................E132 Z
............................................Interior burglary
Interior delay 1 .................................. E132 Z
............................................Interior burglary
Interior delay 2 .................................. E132 Z
............................................Interior burglary
Fire .................................................... E110 Z
............................................Fire alarm
Panic .................................................E120 Z
............................................Panic alarm
Silent panic .......................................E122 Z
............................................Silent
Emergency ........................................ E100 Z
............................................Medical
Follower ............................................ E132 Z
............................................Interior burglary
Auxiliary ...........................................E150 Z
............................................24 hour nonburglary
Duress disarm ...................................E121 0............................................Duress
Duress when not armed .................... E121 0............................................Duress
Zone restore after activation.............. R 140 Z ............................................General Alarm
Transmitter low battery ...................... E384 Z
............................................RF low battery
Transmitter battery restore .................R384 Z............................................RF low battery
Zone trouble .....................................E370 Z
............................................Protection loop
Zone trouble restore .......................... R370 Z............................................Protection loop
High current trouble .......................... E300 91..........................................System trouble
High current restore .......................... R300 91..........................................System trouble
Phone line restore .............................R350 28..........................................Communication
Open (disarm) ...................................E401 U...........................................Open by user
Open after activation ........................ E450 U...........................................Exception open
Close (arm) ........................................ R401 U...........................................Close by user
Force Arm .........................................R450 U...........................................Exception close
Control low battery ...........................E302 29..........................................Low system battery
Control battery restore .......................R302 29..........................................Low system battery
AC fail ...............................................E301 29..........................................AC loss
AC restore .........................................R301 29..........................................AC loss
User communicator test .................... E601 Z
............................................Manual trigger test
Automatic communicator test ...........E602 99..........................................Periodic test report
Cancel ...............................................E406 Z
............................................Cancel
Zone bypass ...................................... E570 Z
............................................Zone bypass
Zone unbypass .................................. R570 Z............................................Zone bypass
Day zone trouble .............................. E135 Z
............................................Day alarm
Day zone trouble restore ...................R135 Z............................................Day alarm
Upload/download attempt .................E412 99..........................................Success - download/access
Program mode entry .......................... E627 99..........................................Program mode entry
Fail to open .......................................E453 99..........................................Failed to open
Fail to close .......................................E454 99..........................................Failed to close
Zone open .........................................E371 Z
............................................Protection Loop
Zone restore ...................................... R371 Z............................................Protection Loop
Tamper .............................................. E 383 Z ............................................Zone tamper
Tamper Restore.................................. R383 Z............................................Zone tamper restore
Receiver Supervision Trouble ............ E 355 Z ............................................Loss of radio supervision
Receiver Supervision Trouble Restore R 355 Z ............................................Loss of radio supervision