24

Zones 18 - 23: Alarm Type Transmitters Continued

Zone 18 Zone 19
Input Transmitter 9 Serial #: Input Transmitter 10 Serial #:
Option Location Default New Va lue Option Location Default New Va lue
Device 1248 005 Device 1260 005
Loop 1245 130 Loop 1257 130
Zone Type 0919 255 Zone Type 0935 255
Option 1 0915 080 Option 1 0931 080
Option 2 0916 000 Option 2 0932 000
Word 1 Word 3 Word 1 Word 3
Word 2 Word 4 Word 2 Word 4
Zone 20 Zone 21
Input Transmitter 11 Serial #: Input Transmitter 12 Serial #:
Option Location Default New Va lue Option Location Default New Va lue
Device 1272 005 Device 1284 005
Loop 1269 130 Loop 1281 130
Zone Type 0951 255 Zone Type 0967 255
Option 1 0947 080 Option 1 0963 080
Option 2 0948 000 Option 2 0964 000
Word 1 Word 3 Word 1 Word 3
Word 2 Word 4 Word 2 Word 4
Zone 22 Zone 23
Input Transmitter 13 Serial #: Input Transmitter 14 Serial #:
Option Location Default New Va lue Option Location Default New Va lue
Device 1296 005 Device 1308 005
Loop 1293 130 Loop 1305 130
Zone Type 0983 255 Zone Type 0999 255
Option 1 0979 080 Option 1 0995 080
Option 2 0980 000 Option 2 0996 000
Word 1 Word 3 Word 1 Word 3
Word 2 Word 4 Word 2 Word 4

Zones 24 - 25: Portable Transmitters

To program a portable transmitter's serial number, enter 9940 in program mode. The system will prompt "Enter
Zone." Enter the zone number (24). The panel will repeat the zone number and prompt "Enter Seven." Enter the
seven digit serial number that appears on the bar code of the transmitter (Ignore the leading letter). The panel will
prompt for the next zone. Enter the next transmitter zone number or "H" to exit.
Both of the portable transmitters are defaulted as 5804s. To use a different portable transmitter, choose the device
from the list on the next page and place the appropriate value in the Device location.
Each of functions that can be programmed to a button are listed in the Button Function table. Program the
appropriate button with the button function value. For a description of how each button function operates see
"Button Functions" in the Glossary at the end of this manual. If a transmitter has less than 4 buttons enter 255 in the
additional button function locations.
Option 1 value 016 (report to central station) is the only Zone Option that applies to zones 24 - 25. To prevent
portable transmitter activations from reporting to the central station, enter 000 in the option 1 location.