31

System Options - Group 1

Options - Enter Total - A description of each option is available in the Glossary Location Value
Disarm before rearm ...................................................................................................................... 004
Mute external Speaker (external driver -off, internal driver - adjustable) ........................................ 008
Access code before arm ................................................................................................................. 016
Speak pre-alarm instead of tone ..................................................................................................... 032
3 digit disarm code ........................................................................................................................ 064
Speak system status with 1st digit of a user code ............................................................................ 128
Default ......................................................................................................................... 0074 ....... 164

System Options - Group 2

Options - Enter Total - A description of each option is available in the Glossary Location Value
*Trigger a relay from a portable transmitter or keypad ................................................................... 002
Automatic "force arm" (no second key press) (Not permitted in a UL installation) ......................... 004
No exterior instant exit delay ......................................................................................................... 008
No entry delay for Exterior Delay 1 in HOME mode ...................................................................... 016
Auto 96 hr clear of long term memory and event memory log ....................................................... 032
Zone trouble = zone activation when armed ................................................................................. 064
Default ......................................................................................................................... 0075 ....... 000
* A button function must be assigned in order to restore trigger

System Options - Group 3

Options - Enter Total - A description of each option is available in the Glossary Location Value
Speak time remaining and end of exit delay (inside speaker every 10 seconds) ............................. 001
Track activations and record in Long Term Memory....................................................................... 002
Voice driver ................................................................................................................................... 004
Echo local phone speech to inside speaker .................................................................................... 016
Enable night mode ......................................................................................................................... 032
Enable two-way voice call back (Not permitted in a UL installation) ............................................. 064
Default ......................................................................................................................... 0076 ....... 039

System Options - Group 4

Options - Enter Total - A description of each option is available in the Glossary Location Value
Prevent access to Program Mode when armed .............................................................................. 001
Suppress Dialer during 2-way callback wait period (Not permitted in a UL installation ................. 128
Default ......................................................................................................................... 0077 ....... 000

System Options - Group 5

Options - Enter Total - A description of each option is available in the Glossary Location Value
Speak auxiliary zone type .............................................................................................................. 001
Speak status immediately after local phone access ........................................................................ 002
Silence inside speaker in Home/Night mode (Not permitted in a UL installation) ......................... 004
Speak zone description in Extended Monitor ................................................................................. 008
Disable force arming (For UL installations this option must be enabled) ........................................ 064
Default ......................................................................................................................... 0078 ....... 009

System Options - Group 6

Options - Enter Total - A description of each option is available in the Glossary Location Value
Speak time and date when time is requested ................................................................................. 002
Enable answer service override callback ....................................................................................... 008
Default ......................................................................................................................... 0079 ....... 000