32

Monitor Trouble Conditions

Option - A description of each option is available in the Glossary Location Value
* Monitor low battery and enable battery test (001 to enable) ....................................... 0180 ....... 000
* Communicator fail (001 to enable)............................................................................. 0181 ....... 001
* 000 disables (Must be enabled for UL installation)

Bypass Options

Option: Enter Total - A description of each option is available in the Glossary Location Value
Open zones automatically bypassed at force arm ....................................................................... 001
Zones bypassed by force arm auto unbypassed at disarm ........................................................... 002
Unbypass all bypassed zones automatically at disarm ................................................................... 004
Default (Force Armed zones reactivated when shut) ................................................... 0182 ....... 000

Extended Monitor Zone Type Assignment

Zone Types - Enter Total for Extended Monitor A Location Value
Exterior instant ............................................................................................................................... 001
Exterior delay 1.............................................................................................................................. 002
Exterior delay 2.............................................................................................................................. 004
Interior instant................................................................................................................................008
Interior delay 1 .............................................................................................................................. 016
Interior delay 2 .............................................................................................................................. 032
Follower ........................................................................................................................................ 064
Auxiliary 1 and 2 ........................................................................................................................... 128
Default ......................................................................................................................... 0177 ....... 001
Zone Types - Enter Total for Extended Monitor B Location Value
Exterior instant ............................................................................................................................... 001
Exterior delay 1.............................................................................................................................. 002
Exterior delay 2.............................................................................................................................. 004
Interior instant................................................................................................................................008
Interior delay 1 .............................................................................................................................. 016
Interior delay 2 .............................................................................................................................. 032
Follower ........................................................................................................................................ 064
Auxiliary 1 and 2 ........................................................................................................................... 128
Default ......................................................................................................................... 0178 ....... 007
With the system disarmed, entering a full function user code followed by the 3 or 4 digit, will place the system into
extended monitor mode A or B. The system will speak "MONITOR ON" through the inside speaker. Entering a full
function user code followed by 3 or 4 will clear any active extended monitor zones and stop the extended monitor beep or
speech. The system will speak "MONITOR RESTORED." If the system is in extended monitor mode and there are no
extended monitor zones active, entering a full function user code followed by 3 or 4 will take the system out of extended
monitor mode. The system will speak "MONITOR OFF".
The enunciation feature of the control panel can be used to monitor exterior, interior, and follower zones. As an example,
it may be desirable to monitor interior door activity of residents in a retirement home. Normal extended monitor activity is
not sent to the central station. If a Day Zone causes an Extended Monitor activation when the system is not armed, a Day
Zone Trouble can be sent to the central station.
There are two different levels or types of extended monitor, A and B. Locations 0177 and 0178 determine which zone
types are to be monitored by each extended monitor type. Entering a full function user code followed by the digit 3 will
place the system in extended monitor mode type A or enter the 4 digit for extended monitor type B. When entering
extended monitor the system responds with "MONITOR ON" through the inside speaker.
NOTE: You can only enter the extended monitor mode when the system is disarmed. If the system is in extended monitor
mode it will automatically exit that mode when the system is armed.