20

Programming Zones

The device types for each zone on the Destiny 4100 are predefined. The device assignments are fixed and may not
be modified.
Zones 1-8: Hardware Inputs 1-8 on the system controller
Zone 9: Two-Wire Smoke loop
Zone 10 - 23: 14 Wireless Alarm Point Transmitters
Zone 24 - 25: 2 Wireless Portable Transmitters
Zone 26: System Keypad
Zone 27: Local Phone Activation
Zone 28: Remote Phone Activation / Phone Line Monitor
Zone 29: Monitor Trouble Contitions
Each hardware type can be found on the following pages. Under each heading are detailed instructions on how to
program the hardware type. For a full description of any of the following zone options, please consult the Glossary
in the rear of the manual.

These Options are Common to Each Zone Section

Zone Type

Type Value
Exterior Instant .............................................................................................................. 000
Exterior Delay 1 ............................................................................................................ 001
Exterior Delay 2 ............................................................................................................ 002
Interior Instant............................................................................................................... 003
Interior Delay 1............................................................................................................. 004
Interior Delay 2............................................................................................................. 005
Fire ............................................................................................................................... 006
Panic ............................................................................................................................ 007
Silent Panic ................................................................................................................... 008
Emergency .................................................................................................................... 009
Follower ....................................................................................................................... 010
Aux Type 1.................................................................................................................... 011
Aux Type 2.................................................................................................................... 012
Day Zone ...................................................................................................................... 013
Step arming................................................................................................................... 014
Disable ......................................................................................................................... 255

Zone Options 1

Options - Enter Total Value
Report Alarm Activation to Central Station ................................................................... 016
Display open status at keypad....................................................................................... 064
Default ......................................................................................................................... 000

Zone Options 2

Options - Enter Total Value
Suppress Speech/Beeps for monitor .............................................................................. 016
Suppress OPEN from being spoken during monitor ................................................... 032
Suppress siren on activation .......................................................................................... 064
Default ......................................................................................................................... 000