22
Zone 9
Input 2-Wire Sm oke
Option Location Default New Va lue Default Description
Zone Type 0775 255 Word 1 Word 2 Word 3 Word 4
Option 1 0771 016 Smoke (151 ) Detector (057) N/A N/A
Option 2 0772 000

5819

Loop 3
Loop 2
Loop 1
(Shock Input)
Loop 1
Loop 2

5816 (MN) 5817

Loop 3Loop 2Loop 1

Zone 9: System Controller Two-Wire Smoke Loop

At default, the two wire smoke loop is disabled. To enable the loop, enter 0775,006 (Zone type Fire). The word
description is predefined as "Smoke Detector." This can be changed by altering the zone description for zone 9.
Programming zone descriptions is covered at the end of this section.

Zones 10 - 23: Alarm Type Transmitters

At default, all 14 alarm point transmitters are disabled. To enable a transmitter, enter a zone type in the zone type
location and program a serial number.
Example: To enable Zone 10 (Transmitter 1) and assign it as an Exterior Instant, enter 0791,000.
To program a serial number, enter 9940 in program mode. The system will prompt "Enter Zone." Enter the zone
number (10). The panel will repeat the zone number and prompt "Enter Seven." Enter the seven digit serial number
that appears on the bar code of the transmitter (Ignore the leading letter). The panel will prompt for the next zone.
Enter the next transmitter zone number or "H" to exit.
Each of the 14 transmitter zones are defaulted as a supervised 5817 using loop 2. To use a different alarm point
device, choose the device from the list below and place the appropriate value in the Device location using the chart
on the following page.
Alarm Point Transmitters
Type Description Value
5816 (MN) .......................... 2 input alarm point transmitter ........................................ 003
5816TEMP .......................... Low temperature transmitter ............................................ 004
5817 ................................... 3 input alarm point transmitter ........................................ 005
5818 ................................... Recessed door transmitter ................................................ 006
5819 ................................... 3 input shock transmitter ................................................. 007
5890 ................................... Passive Infrared................................................................ 011
5849 ................................... Shock / Glass Detector .................................................... 012
5806 ................................... Smoke Detector ............................................................... 018
5807 ................................... Smoke Detector ............................................................... 018
5808 ................................... Smoke Detector ............................................................... 019